Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey. (13th March 2018)
- Record Type:
- Journal Article
- Title:
- Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey. (13th March 2018)
- Main Title:
- Diagnostic reference levels for common computed tomography (CT) examinations: results from the first Nigerian nationwide dose survey
- Authors:
- Ekpo, Ernest U
Adejoh, Thomas
Akwo, Judith D
Emeka, Owujekwe C
Modu, Ali A
Abba, Mohammed
Adesina, Kudirat A
Omiyi, David O
Chiegwu, Uche H - Abstract:
- Abstract: Purpose . To explore doses from common adult computed tomography (CT) examinations and propose national diagnostic reference levels (nDRLs) for Nigeria. Materials and Methods . This retrospective study was approved by the Nnamdi Azikiwe University and University Teaching Hospital Institutional Review Boards (IRB: NAUTH/CS/66/Vol8/84) and involved dose surveys of adult CT examinations across the six geographical regions of Nigeria and Abuja from January 2016 to August 2017. Dose data of adult head, chest and abdomen/pelvis CT examinations were extracted from patient folders. The median, 75th and 25th percentile CT dose index volume (CTDIvol ) and dose-length-product (DLP) were computed for each of these procedures. Effective doses (E) for these examinations were estimated using the k conversion factor as described in the ICRP publication 103 (EDLP = k × DLP ). Results . The proposed 75th percentile CTDIvol for head, chest, and abdomen/pelvis are 61 mGy, 17 mGy, and 20 mGy, respectively. The corresponding DLPs are 1310 mGy.cm, 735 mGy.cm, and 1486 mGy.cm respectively. The effective doses were 2.75 mSv (head), 10.29 mSv (chest), and 22.29 mSv (abdomen/pelvis). Conclusion . Findings demonstrate wide dose variations within and across centres in Nigeria. The results also show CTDIvol comparable to international standards, but considerably higher DLP and effective doses.
- Is Part Of:
- Journal of radiological protection. Volume 38:Number 2(2018:Jun.)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 38:Number 2(2018:Jun.)
- Issue Display:
- Volume 38, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 2
- Issue Sort Value:
- 2018-0038-0002-0000
- Page Start:
- 525
- Page End:
- 535
- Publication Date:
- 2018-03-13
- Subjects:
- CTDIvol -- DLP -- DRLs -- radiation dose -- effective dose -- 75th percentile
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/aaaaf8 ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11269.xml