International spinal cord injury urodynamic basic data set (version 2.0). (December 2018)
- Record Type:
- Journal Article
- Title:
- International spinal cord injury urodynamic basic data set (version 2.0). (December 2018)
- Main Title:
- International spinal cord injury urodynamic basic data set (version 2.0)
- Authors:
- Pannek, Jürgen
Kennelly, Michael
Kessler, Thomas
Linsenmeyer, Todd
Wyndaele, Jean-Jacques
Biering-Sørensen, Fin - Abstract:
- Abstract Study design: Revision, review, and presentation of the International Spinal Cord Injury (SCI) Urodynamic Basic Data Set (version 2.0). Objectives: Describe the revision and review and present the dataset. Setting: International. Methods: The first version of the dataset was revised according to new knowledge and suggestions. The review included International SCI Data Sets Committee, American Spinal Injury Association (ASIA) board, International Spinal Cord Society (ISCoS) executive and scientific committees, major organizations, and interested individuals. The dataset was also on ASIA and ISCoS websites. All replies were answered and appropriate adjustments made. Finally, the dataset was endorsed by ASIA board, and ISCoS executive and scientific committees. Results: Among revisions are adoptions of new terminology by the International Continence Society. The variable "Detrusor function" has been divided into "Detrusor function during filling cystometry" and "Detrusor function during voiding". The response categories have been adjusted, deleting 'Not applicable' for the variables "Detrusor leak point pressure during filling cystometry", "Cystometric bladder capacity during filling cystometry" and "Urethral function during voiding". The cutoff-value for low bladder compliance has been modified from 10 mL/cm H2 O to 20 mL/cm H2 O. Conclusions: The International SCI Urodynamic Basic Data Set (version 2.0) with its complete syllabus is availableAbstract Study design: Revision, review, and presentation of the International Spinal Cord Injury (SCI) Urodynamic Basic Data Set (version 2.0). Objectives: Describe the revision and review and present the dataset. Setting: International. Methods: The first version of the dataset was revised according to new knowledge and suggestions. The review included International SCI Data Sets Committee, American Spinal Injury Association (ASIA) board, International Spinal Cord Society (ISCoS) executive and scientific committees, major organizations, and interested individuals. The dataset was also on ASIA and ISCoS websites. All replies were answered and appropriate adjustments made. Finally, the dataset was endorsed by ASIA board, and ISCoS executive and scientific committees. Results: Among revisions are adoptions of new terminology by the International Continence Society. The variable "Detrusor function" has been divided into "Detrusor function during filling cystometry" and "Detrusor function during voiding". The response categories have been adjusted, deleting 'Not applicable' for the variables "Detrusor leak point pressure during filling cystometry", "Cystometric bladder capacity during filling cystometry" and "Urethral function during voiding". The cutoff-value for low bladder compliance has been modified from 10 mL/cm H2 O to 20 mL/cm H2 O. Conclusions: The International SCI Urodynamic Basic Data Set (version 2.0) with its complete syllabus is available fromhttp://www.iscos.org.uk/international-sci-data-sets . … (more)
- Is Part Of:
- Spinal cord series and cases. Volume 4(2018)
- Journal:
- Spinal cord series and cases
- Issue:
- Volume 4(2018)
- Issue Display:
- Volume 4, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 4
- Issue:
- 2018
- Issue Sort Value:
- 2018-0004-2018-0000
- Page Start:
- 1
- Page End:
- 5
- Publication Date:
- 2018-12
- Subjects:
- Spinal cord -- Wound and injuries -- Periodicals
Spinal cord -- Diseases -- Periodicals
617.482044 - Journal URLs:
- http://www.nature.com/scsandc/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1038/s41394-018-0133-0 ↗
- Languages:
- English
- ISSNs:
- 2058-6124
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.896000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11266.xml