A predictive algorithm for spot position corrections after fast energy switching in proton pencil beam scanning. Issue 11 (16th October 2018)
- Record Type:
- Journal Article
- Title:
- A predictive algorithm for spot position corrections after fast energy switching in proton pencil beam scanning. Issue 11 (16th October 2018)
- Main Title:
- A predictive algorithm for spot position corrections after fast energy switching in proton pencil beam scanning
- Authors:
- Psoroulas, Serena
Bula, Christian
Actis, Oxana
Weber, Damien Charles
Meer, David - Abstract:
- Abstract : Purpose: Fast energy switching is of fundamental importance to implement motion mitigation techniques in pencil beam scanning proton therapy, allowing efficient irradiation and high patient throughput. However, depending on magnet design, when switching between different energy layers, eddy currents arise in the bending magnets' yoke, damping the speed of the magnetic field change and lengthening the settling time of the magnetic field. In a proton therapy gantry, this can cause a temporary displacement of the beam trajectory and consequently an incorrect beam position in the bending direction, resulting in an unacceptable loss of position precision at isocenter. The precision can be recovered by either increasing the beam off time after an energy change (waiting until the magnetic field is fully settled) or by actively correcting for the misplacement. We studied the transient magnetic field effects at PSI Gantry 2 in order to develop a correction strategy for this beam position misplacement. Methods: We used position and proton range sensitive detectors (segmented strip chamber and multilayer ionization chambers respectively) to measure the difference between expected and actual proton beam position and range as a function of time. The detectors are automatically triggered, read out, and analyzed by the treatment control system. We studied the effects due to the magnets on the gantry and those upstream of the gantry separately, in order to identify which elementsAbstract : Purpose: Fast energy switching is of fundamental importance to implement motion mitigation techniques in pencil beam scanning proton therapy, allowing efficient irradiation and high patient throughput. However, depending on magnet design, when switching between different energy layers, eddy currents arise in the bending magnets' yoke, damping the speed of the magnetic field change and lengthening the settling time of the magnetic field. In a proton therapy gantry, this can cause a temporary displacement of the beam trajectory and consequently an incorrect beam position in the bending direction, resulting in an unacceptable loss of position precision at isocenter. The precision can be recovered by either increasing the beam off time after an energy change (waiting until the magnetic field is fully settled) or by actively correcting for the misplacement. We studied the transient magnetic field effects at PSI Gantry 2 in order to develop a correction strategy for this beam position misplacement. Methods: We used position and proton range sensitive detectors (segmented strip chamber and multilayer ionization chambers respectively) to measure the difference between expected and actual proton beam position and range as a function of time. The detectors are automatically triggered, read out, and analyzed by the treatment control system. We studied the effects due to the magnets on the gantry and those upstream of the gantry separately, in order to identify which elements contribute the most to the beam position instability. We then designed a spot position algorithm to be applied with the gantry scanning magnets, to correct for the displacement observed as a function of time and achieve the PSI Gantry 2 clinical target of 1 mm precision at isocenter at all times, even after an energy change. Results: When switching energy layers in a field, we observed an exponentially decaying spot position displacement at isocenter. The effect increases with increasing energy difference between energy layers (ΔE). The initial residuals between expected and measured position are higher than 1 mm for most of the clinical cases at Gantry 2 and fall below 1 mm within about 1 s or more (depending on ΔE). We found no time dependence for the proton range, thus confirming that the displacement is purely due to a beam trajectory displacement resulting from the longer settling time of the magnetic field. A double exponential model, with two time constants and amplitudes depending on ΔE, fits the data and provides an easy model for the correction function. We implemented this correction as a spot position correction, applied by the scanning magnets during field application. After correction, the residuals were below 0.5 mm right after the energy change. Conclusions: We developed a spot position correction for PSI Gantry 2 which reduces the beam off time needed in current state‐of‐the‐art gantries to settle the magnetic fields in the bending magnets. Thanks to this correction, the spot position is stable within 100 ms of an energy change at Gantry 2. This is low enough to make possible efficient use of motion mitigation techniques. … (more)
- Is Part Of:
- Medical physics. Volume 45:Issue 11(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 11(2018)
- Issue Display:
- Volume 45, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 11
- Issue Sort Value:
- 2018-0045-0011-0000
- Page Start:
- 4806
- Page End:
- 4815
- Publication Date:
- 2018-10-16
- Subjects:
- beam position precision -- gantry -- magnet dynamics -- pencil beam scanning -- proton therapy
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13217 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11229.xml