Toward a novel dosimetry system using acrylic disk radiation sensor for proton pencil beam scanning. Issue 11 (27th September 2018)
- Record Type:
- Journal Article
- Title:
- Toward a novel dosimetry system using acrylic disk radiation sensor for proton pencil beam scanning. Issue 11 (27th September 2018)
- Main Title:
- Toward a novel dosimetry system using acrylic disk radiation sensor for proton pencil beam scanning
- Authors:
- Cho, Shinhaeng
Lee, Nuri
Song, Sanghyeon
Son, Jaeman
Kim, Haksoo
Jeong, Jong Hwi
Lee, Se Byeong
Lim, Youngkyung
Moon, Sunyoung
Yoon, Myonggeun
Shin, Dongho - Abstract:
- Abstract : Purpose: Fabricate an acrylic disk radiation sensor (ADRS) and characterize the photoluminescence signal generated from the optical device as basis for the development and evaluation of a new dosimetry system for pencil beam proton therapy. Methods: Based on the characteristics of the proposed optical dosimetry sensor, we established the relation between the photoluminescence output and the applied dose using an ionization chamber. Then, we obtained the relative integral depth dose profiles using the photoluminescence signal generated by pencil beam irradiation at energies of 99.9 and 162.1 MeV, and compared the results with the curve measured using a Bragg peak ionization chamber. Results: The relation between the photoluminescence output and applied dose was linear. In addition, the ADRS was dose independent for beam currents up to 6 Gy/min, and the calibration factor for energy was close to 1. Hence, the energy dependence on the optical device can be disregarded. The integral depth dose profiles obtained for the ADRS suitable agreed with the curve measured in the Bragg peak ionization chamber without requiring correction. Conclusions: These results suggest that the ADRS is suitable for dosimetry measurements in pencil beam scanning, and it will be employed as a low‐cost and versatile dosimetry sensor in upcoming developments.
- Is Part Of:
- Medical physics. Volume 45:Issue 11(2018)
- Journal:
- Medical physics
- Issue:
- Volume 45:Issue 11(2018)
- Issue Display:
- Volume 45, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 45
- Issue:
- 11
- Issue Sort Value:
- 2018-0045-0011-0000
- Page Start:
- 5277
- Page End:
- 5282
- Publication Date:
- 2018-09-27
- Subjects:
- acrylic disk -- Bragg ionization chamber -- integral depth‐dose -- pencil beam scanning
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1002/mp.13149 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11229.xml