Comparison of Flow Cytometric Methods for the Enumeration of Residual Leucocytes in Leucoreduced Blood Products: A Multicenter Study. Issue 4 (18th January 2018)
- Record Type:
- Journal Article
- Title:
- Comparison of Flow Cytometric Methods for the Enumeration of Residual Leucocytes in Leucoreduced Blood Products: A Multicenter Study. Issue 4 (18th January 2018)
- Main Title:
- Comparison of Flow Cytometric Methods for the Enumeration of Residual Leucocytes in Leucoreduced Blood Products: A Multicenter Study
- Authors:
- Zeng, Yang
Dabay, Michelle
George, Virginia
Seetharaman, Shalini
de Arruda Indig, Monika
Graminske, Sharon
Kimpel, Nicole
Schmidt, Anna
Boerner, Amanda
Paradiso, Sarai
Delman, Tatyana
Li, Yunyao
Litvak, Viktoriya
Oreizy, Farzad
Chen, Angela
Saleminik, Maryam
Mosqueda, Fred
Lin, Anna
Judge, Kevin - Abstract:
- Abstract: The BD FACSVia™ System features novel designs in hardware, software, and instrument QC. We compared the performance of the BD FACSVia System using the BD Leucocount™ kit with the BD FACSCalibur™ flow cytometer. Leucoreduced platelet (PLT, n = 252) and red blood cell (RBC, n = 278) specimens were enrolled at four sites. Each specimen was stained in four tubes using the BD Leucocount kit reagents and acquired on the two systems. BD Leucocount Control cells (high and low) were used to evaluate the inter‐site reproducibility on the BD FACSVia System at three sites over 20 days. Deming regression and Bland–Altman analysis were performed to determine the WBC absolute counts on the BD FACSVia System vs. the BD FACSCalibur system. Assay accuracy for the range of 0–350 WBCs/µl was adequate. For samples with <25 WBCs/µl, the bias with 95% limits of agreement was 0.136 (–1.897 to 2.169) WBC/µl for PLTs ( n = 184) and 0.170 (–2.025 to 2.365) WBC/µl for RBCs ( n = 193). For inter‐site reproducibility, the CV% was 6.46% (upper 95% CI 7.16%) for the PLT high control and 9.49% (10.52%) for the PLT low control. The CV% was 7.51% (8.32%) for the RBC high control and 10.76% (11.92%) for the RBC low control. The BD FACSVia System reported equivalent results of WBC absolute counts for leucoreduced PLT and RBC samples compared to the BD FACSCalibur system. The inter‐laboratory reproducibility of the BD FACSVia System met study specifications. © 2018 The Authors. Cytometry Part AAbstract: The BD FACSVia™ System features novel designs in hardware, software, and instrument QC. We compared the performance of the BD FACSVia System using the BD Leucocount™ kit with the BD FACSCalibur™ flow cytometer. Leucoreduced platelet (PLT, n = 252) and red blood cell (RBC, n = 278) specimens were enrolled at four sites. Each specimen was stained in four tubes using the BD Leucocount kit reagents and acquired on the two systems. BD Leucocount Control cells (high and low) were used to evaluate the inter‐site reproducibility on the BD FACSVia System at three sites over 20 days. Deming regression and Bland–Altman analysis were performed to determine the WBC absolute counts on the BD FACSVia System vs. the BD FACSCalibur system. Assay accuracy for the range of 0–350 WBCs/µl was adequate. For samples with <25 WBCs/µl, the bias with 95% limits of agreement was 0.136 (–1.897 to 2.169) WBC/µl for PLTs ( n = 184) and 0.170 (–2.025 to 2.365) WBC/µl for RBCs ( n = 193). For inter‐site reproducibility, the CV% was 6.46% (upper 95% CI 7.16%) for the PLT high control and 9.49% (10.52%) for the PLT low control. The CV% was 7.51% (8.32%) for the RBC high control and 10.76% (11.92%) for the RBC low control. The BD FACSVia System reported equivalent results of WBC absolute counts for leucoreduced PLT and RBC samples compared to the BD FACSCalibur system. The inter‐laboratory reproducibility of the BD FACSVia System met study specifications. © 2018 The Authors. Cytometry Part A Published by Wiley Periodicals, Inc. on behalf of ISAC. … (more)
- Is Part Of:
- Cytometry. Volume 93:Issue 4(2018)
- Journal:
- Cytometry
- Issue:
- Volume 93:Issue 4(2018)
- Issue Display:
- Volume 93, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 93
- Issue:
- 4
- Issue Sort Value:
- 2018-0093-0004-0000
- Page Start:
- 420
- Page End:
- 426
- Publication Date:
- 2018-01-18
- Subjects:
- leucodepletion -- leucoreduced -- residual Leucocytes -- flow cytometry -- performance evaluation
Flow cytometry -- Periodicals
Imaging systems in biology -- Periodicals
Imaging systems in medicine -- Periodicals
Diagnostic imaging -- Periodicals
571.605 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1552-4930 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/cyto.a.23318 ↗
- Languages:
- English
- ISSNs:
- 1552-4922
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3506.855100
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11224.xml