Reponen, Tiina - Abstract:
- Abstract: The objective of the National Institute for Occupational Safety and Health (NIOSH) accuracy criterion is to ensure that measurements from monitoring devices are within ±25% of the true concentration of the analyte with 95% certainty. To determine whether NO2 and O3 sensors meet this criterion, three commercially available units (Cairclip O3 /NO2, Aeroqual NO2, and Aeroqual O3 sensors) were co-located three times with validated instruments (NOx chemiluminescence [NO2mon ] and photometric O3 analyzers [O3mon ]) at an outdoor monitoring station. As cofactors of sensor performance such as temperature (T) and relative humidity (RH) potentially influence the response of NO2 and O3 sensors, corrections for cofactors were made by using T, RH, and the sensor measurements to predict measurements made by NO2mon and O3mon during the first co-location period (training dataset). The developed models were tested in the merged data obtained from the second and third co-location periods (testing dataset). In the training and testing datasets, the mean NO2 as measured by NO2mon was 4.6 ppb (range = 0.4–35 ppb) and 9.4 ppb (range = 1–37 ppb), respectively. The mean O3 in the training and testing datasets as measured by O3mon was 38.8 ppb (range = 1–65 ppb) and 35.7 ppb (range = 1–61 ppb), respectively. None of the sensor measurements in the training dataset were within the NIOSH accuracy criterion (mean error ≥25%). After correcting for cofactors of sensor performance, the accuracyAbstract: The objective of the National Institute for Occupational Safety and Health (NIOSH) accuracy criterion is to ensure that measurements from monitoring devices are within ±25% of the true concentration of the analyte with 95% certainty. To determine whether NO2 and O3 sensors meet this criterion, three commercially available units (Cairclip O3 /NO2, Aeroqual NO2, and Aeroqual O3 sensors) were co-located three times with validated instruments (NOx chemiluminescence [NO2mon ] and photometric O3 analyzers [O3mon ]) at an outdoor monitoring station. As cofactors of sensor performance such as temperature (T) and relative humidity (RH) potentially influence the response of NO2 and O3 sensors, corrections for cofactors were made by using T, RH, and the sensor measurements to predict measurements made by NO2mon and O3mon during the first co-location period (training dataset). The developed models were tested in the merged data obtained from the second and third co-location periods (testing dataset). In the training and testing datasets, the mean NO2 as measured by NO2mon was 4.6 ppb (range = 0.4–35 ppb) and 9.4 ppb (range = 1–37 ppb), respectively. The mean O3 in the training and testing datasets as measured by O3mon was 38.8 ppb (range = 1–65 ppb) and 35.7 ppb (range = 1–61 ppb), respectively. None of the sensor measurements in the training dataset were within the NIOSH accuracy criterion (mean error ≥25%). After correcting for cofactors of sensor performance, the accuracy of the Cairclip O3 /NO2 and the Aeroqual O3 sensors considerably improved when tested with the testing dataset (mean error = -1% and 14%, respectively). However, the Aeroqual NO2 sensor had an error that was not within ±25%. Raw measurements from the tested sensors may be unsuitable for assessing workers' exposure to NO2 and O3 . Corrections for cofactors of Cairclip O3 /NO2 and Aeroqual O3 sensor performance are required for more accurate occupational exposure assessment. … (more)
- Is Part Of:
- Journal of occupational and environmental hygiene. Volume 15:Issue 11(2018)
- Journal:
- Journal of occupational and environmental hygiene
- Issue:
- Volume 15:Issue 11(2018)
- Issue Display:
- Volume 15, Issue 11 (2018)
- Year:
- 2018
- Volume:
- 15
- Issue:
- 11
- Issue Sort Value:
- 2018-0015-0011-0000
- Page Start:
- 782
- Page End:
- 791
- Publication Date:
- 2018-11-02
- Subjects:
- Aeroqual -- Cairclip -- direct-reading instruments -- low-cost sensors
Industrial hygiene -- Periodicals
Environmental health -- Periodicals
Medicine, Industrial -- Periodicals
Occupational Health -- Periodicals
Environmental Exposure -- Periodicals
Environmental Health -- Periodicals
Occupational Exposure -- Periodicals
Hygiène industrielle -- Périodiques
Hygiène du milieu -- Périodiques
Médecine du travail -- Périodiques
613.62 - Journal URLs:
- http://www.tandfonline.com/ ↗
- DOI:
- 10.1080/15459624.2018.1513135 ↗
- Languages:
- English
- ISSNs:
- 1545-9624
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5026.080500
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11228.xml