Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer. (February 2017)
- Record Type:
- Journal Article
- Title:
- Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer. (February 2017)
- Main Title:
- Characterizing the reduction of stimulation artifact noise in a tripolar nerve cuff electrode by application of a conductive shield layer
- Authors:
- Sabetian, Parisa
Sadeghlo, Bita
Zhang, Chengran Harvey
Yoo, Paul B - Abstract:
- Highlights: A method is proposed for significantly improving peripheral nerve recording. The method relies on a conductive shield layer (CSL) to divert artifact current. Computer simulations show an 85% decrease in the recorded artifact signal. In vivo study confirms the effects of the CSL for a tripolar nerve cuff electrode. Abstract: Tripolar nerve cuff electrodes have been widely used for measuring peripheral nerve activity. However, despite the high signal-to-noise ratio levels that can be achieved with this recording configuration, the clinical use of cuff electrodes in closed-loop controlled neuroprostheses remains limited. This is largely attributed to artifact noise signals that contaminate the recorded neural activity. In this study, we investigated the use of a conductive shield layer (CSL) as a means of reducing the artifact noise recorded by nerve cuff electrodes. Using both computational simulations and in vivo experiments, we found that the CSL can result in up to an 85% decrease in the recorded artifact signal. Both the electrical conductivity and the surface area of the CSL were identified as important design criteria. Although this study shows that the CSL can significantly reduce artifact noise in tripolar nerve cuff electrodes, long-term implant studies are needed to validate our findings.
- Is Part Of:
- Medical engineering & physics. Volume 40(2017)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 40(2017)
- Issue Display:
- Volume 40, Issue 2017 (2017)
- Year:
- 2017
- Volume:
- 40
- Issue:
- 2017
- Issue Sort Value:
- 2017-0040-2017-0000
- Page Start:
- 39
- Page End:
- 46
- Publication Date:
- 2017-02
- Subjects:
- Peripheral nerve recording -- Artifact signal -- Single fiber -- Action potential -- Finite element model -- Neuroprosthesis
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2016.11.010 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11219.xml