Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis. (November 2018)
- Record Type:
- Journal Article
- Title:
- Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis. (November 2018)
- Main Title:
- Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis
- Authors:
- Si, Xiang
Xu, Hailin
Liu, Zimeng
Wu, Jianfeng
Cao, Daiyin
Chen, Juan
Chen, Minying
Liu, Yongjun
Guan, Xiangdong - Abstract:
- Abstract : BACKGROUND: We performed a systematic review and meta-analysis of studies investigating the diagnostic accuracy of respiratory variation in inferior vena cava diameter (ΔIVC) for predicting fluid responsiveness in patients receiving mechanical ventilation. METHODS: MEDLINE, EMBASE, the Cochrane Library, and Web of Science were screened from inception to February 2017. The meta-analysis assessed the pooled sensitivity, specificity, diagnostic odds ratio, and area under the receiver operating characteristic curve. In addition, heterogeneity and subgroup analyses were performed. RESULTS: A total of 12 studies involving 753 patients were included. Significant heterogeneity existed among the studies, and meta-regression indicated that ventilator settings were the main sources of heterogeneity. Subgroup analysis indicated that ΔIVC exhibited better diagnostic performance in the group of patients ventilated with tidal volume (TV) ≥8 mL/kg and positive end-expiratory pressure (PEEP) ⩽5 cm H2 O than in the group ventilated with TV <8 mL/kg or PEEP >5 cm H2 O, as demonstrated by higher sensitivity (0.80 vs 0.66; P = .02), specificity (0.94 vs 0.68; P < .001), diagnostic odds ratio (68 vs 4; P < .001), and area under the receiver operating characteristic curve (0.88 vs 0.70; P < .001). The best ΔIVC threshold for predicting fluid responsiveness was 16% ± 2% in the group of TV ≥8 mL/kg and PEEP ⩽5 cm H2 O, whereas in the group of TV <8 mL/kg or PEEP >5 cm H2 O, this thresholdAbstract : BACKGROUND: We performed a systematic review and meta-analysis of studies investigating the diagnostic accuracy of respiratory variation in inferior vena cava diameter (ΔIVC) for predicting fluid responsiveness in patients receiving mechanical ventilation. METHODS: MEDLINE, EMBASE, the Cochrane Library, and Web of Science were screened from inception to February 2017. The meta-analysis assessed the pooled sensitivity, specificity, diagnostic odds ratio, and area under the receiver operating characteristic curve. In addition, heterogeneity and subgroup analyses were performed. RESULTS: A total of 12 studies involving 753 patients were included. Significant heterogeneity existed among the studies, and meta-regression indicated that ventilator settings were the main sources of heterogeneity. Subgroup analysis indicated that ΔIVC exhibited better diagnostic performance in the group of patients ventilated with tidal volume (TV) ≥8 mL/kg and positive end-expiratory pressure (PEEP) ⩽5 cm H2 O than in the group ventilated with TV <8 mL/kg or PEEP >5 cm H2 O, as demonstrated by higher sensitivity (0.80 vs 0.66; P = .02), specificity (0.94 vs 0.68; P < .001), diagnostic odds ratio (68 vs 4; P < .001), and area under the receiver operating characteristic curve (0.88 vs 0.70; P < .001). The best ΔIVC threshold for predicting fluid responsiveness was 16% ± 2% in the group of TV ≥8 mL/kg and PEEP ⩽5 cm H2 O, whereas in the group of TV <8 mL/kg or PEEP >5 cm H2 O, this threshold was 14% ± 5%. CONCLUSIONS: ΔIVC shows limited ability for predicting fluid responsiveness in distinct ventilator settings. In patients with TV ≥8 mL/kg and PEEP ⩽5 cm H2 O, ΔIVC was an accurate predictor of fluid responsiveness, while in patients with TV <8 mL/kg or PEEP >5 cm H2 O, ΔIVC was a poor predictor. Thus, intensivists must be cautious when using ΔIVC. … (more)
- Is Part Of:
- Anesthesia & analgesia. Volume 127:Number 5(2018)
- Journal:
- Anesthesia & analgesia
- Issue:
- Volume 127:Number 5(2018)
- Issue Display:
- Volume 127, Issue 5 (2018)
- Year:
- 2018
- Volume:
- 127
- Issue:
- 5
- Issue Sort Value:
- 2018-0127-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-11
- Subjects:
- Anesthesiology -- Periodicals
Anesthesia
Anesthesiology
Analgesia
Analgesics
Anesthesiology -- Periodicals
617.9605 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&PAGE=toc&D=ovft&AN=00000539-000000000-00000 ↗
http://journals.lww.com/anesthesia-analgesia/Pages/default.aspx ↗
http://www.anesthesia-analgesia.org ↗
http://journals.lww.com ↗ - DOI:
- 10.1213/ANE.0000000000003459 ↗
- Languages:
- English
- ISSNs:
- 0003-2999
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0900.500000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11229.xml