Assessing the concurrent validity of a gait analysis system integrated into a smart walker in older adults with gait impairments. (October 2019)
- Record Type:
- Journal Article
- Title:
- Assessing the concurrent validity of a gait analysis system integrated into a smart walker in older adults with gait impairments. (October 2019)
- Main Title:
- Assessing the concurrent validity of a gait analysis system integrated into a smart walker in older adults with gait impairments
- Authors:
- Werner, Christian
Chalvatzaki, Georgia
Papageorgiou, Xanthi S
Tzafestas, Costas S
Bauer, Jürgen M
Hauer, Klaus - Abstract:
- Objective: To assess the concurrent validity of a smart walker–integrated gait analysis system with the GAITRite ® system for measuring spatiotemporal gait parameters in potential users of the smart walker. Design: Criterion standard validation study. Setting: Research laboratory in a geriatric hospital. Participants: Twenty-five older adults (⩾65 years) with gait impairments (habitual rollator use and/or gait speed <0.6 m/s) and no severe cognitive impairment (Mini-Mental State Examination ⩾17). Main measures: Stride, swing and stance time; stride length; and gait speed were simultaneously recorded using the smart walker–integrated gait analysis system and the GAITRite system while participants walked along a 7.8-m walkway with the smart walker. Concurrent criterion-related validity was assessed using the Bland–Altman method, percentage errors (acceptable if <30%), and intraclass correlation coefficients for consistency (ICC3, 1 ) and absolute agreement (ICC2, 1 ). Results: Bias for stride, swing and stance time ranged from −0.04 to 0.04 seconds, with acceptable percentage errors (8.7%–23.0%). Stride length and gait speed showed higher bias (meanbias (SD) = 0.20 (0.11) m; 0.19 (0.13) m/s) and not acceptable percentage errors (31.3%–42.3%). Limits of agreement were considerably narrower for temporal than for spatial-related gait parameters. All gait parameters showed good-to-excellent consistency (ICC3, 1 = 0.72–0.97). Absolute agreement was good-to-excellent for temporalObjective: To assess the concurrent validity of a smart walker–integrated gait analysis system with the GAITRite ® system for measuring spatiotemporal gait parameters in potential users of the smart walker. Design: Criterion standard validation study. Setting: Research laboratory in a geriatric hospital. Participants: Twenty-five older adults (⩾65 years) with gait impairments (habitual rollator use and/or gait speed <0.6 m/s) and no severe cognitive impairment (Mini-Mental State Examination ⩾17). Main measures: Stride, swing and stance time; stride length; and gait speed were simultaneously recorded using the smart walker–integrated gait analysis system and the GAITRite system while participants walked along a 7.8-m walkway with the smart walker. Concurrent criterion-related validity was assessed using the Bland–Altman method, percentage errors (acceptable if <30%), and intraclass correlation coefficients for consistency (ICC3, 1 ) and absolute agreement (ICC2, 1 ). Results: Bias for stride, swing and stance time ranged from −0.04 to 0.04 seconds, with acceptable percentage errors (8.7%–23.0%). Stride length and gait speed showed higher bias (meanbias (SD) = 0.20 (0.11) m; 0.19 (0.13) m/s) and not acceptable percentage errors (31.3%–42.3%). Limits of agreement were considerably narrower for temporal than for spatial-related gait parameters. All gait parameters showed good-to-excellent consistency (ICC3, 1 = 0.72–0.97). Absolute agreement was good-to-excellent for temporal (ICC2, 1 = 0.72–0.97) but only poor-to-fair for spatial-related gait parameters (ICC2, 1 = 0.37–0.52). Conclusion: The smart walker–integrated gait analysis system has good concurrent validity with the GAITRite system for measuring temporal but not spatial-related gait parameters in potential end-users of the smart walker. Stride length and gait speed can be measured with good consistency, but with only limited absolute accuracy. … (more)
- Is Part Of:
- Clinical rehabilitation. Volume 33:Number 10(2019)
- Journal:
- Clinical rehabilitation
- Issue:
- Volume 33:Number 10(2019)
- Issue Display:
- Volume 33, Issue 10 (2019)
- Year:
- 2019
- Volume:
- 33
- Issue:
- 10
- Issue Sort Value:
- 2019-0033-0010-0000
- Page Start:
- 1682
- Page End:
- 1687
- Publication Date:
- 2019-10
- Subjects:
- Smart walker -- gait analysis -- elderly -- validity -- assistive devices
Medical rehabilitation -- Periodicals
617.03 - Journal URLs:
- http://cre.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0269215519852143 ↗
- Languages:
- English
- ISSNs:
- 0269-2155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11214.xml