Time to Reconsider the Role of Relative Blood Volume Monitoring for Fluid Management in Hemodialysis. Issue 6 (November 2018)
- Record Type:
- Journal Article
- Title:
- Time to Reconsider the Role of Relative Blood Volume Monitoring for Fluid Management in Hemodialysis. Issue 6 (November 2018)
- Main Title:
- Time to Reconsider the Role of Relative Blood Volume Monitoring for Fluid Management in Hemodialysis
- Authors:
- Keane, David F.
Baxter, Paul
Lindley, Elizabeth
Rhodes, Laura
Pavitt, Sue - Abstract:
- Abstract : Relative blood volume (RBV) monitoring during hemodialysis has been used to help guide fluid management for decades, although with little supporting evidence. The technique relies on the assumption that variation in RBV during fluid removal reflects the capacity for vascular refilling and that efficient refilling is related to fluid overload. This study investigated the relationship between RBV variation and bioimpedance-based fluid overload in 47 patients on stable hemodialysis. Mean treatment ultrafiltration volume (UFV) was 1.7 L and RBV reduction was 3.2%/hour. Relative blood volume slopes were grouped based on trajectory: flatline (no decrease), linear decrease, or linear decrease followed by flatline. Fluid overload was similar ( p > 0.05) across groups pre-dialysis (1.0, 2.2, and 1.6 L, respectively) and post-dialysis (−0.8, −0.1, and −0.1 L), whereas UFV was higher in patients with a linear decrease (1.8, 2.5, and 1.6 L; p = 0.02). Specific ultrafiltration rate, but not fluid overload, was associated with RBV change over dialysis. At least half the patients in each group finished dialysis fluid depleted based on bioimpedance, suggesting that the link between refilling and fluid overload is not as straightforward as previously assumed. These results question the assumptions that the absence of an appreciable decrease in RBV indicates fluid overload, and a rapid fall suggests fluid depletion.
- Is Part Of:
- ASAIO journal. Volume 64:Issue 6(2018)
- Journal:
- ASAIO journal
- Issue:
- Volume 64:Issue 6(2018)
- Issue Display:
- Volume 64, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 64
- Issue:
- 6
- Issue Sort Value:
- 2018-0064-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-11
- Subjects:
- bioimpedance -- blood volume -- fluid management -- hemodialysis
Artificial organs -- Periodicals
617 - Journal URLs:
- http://journals.lww.com/asaiojournal/pages/default.aspx ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MAT.0000000000000795 ↗
- Languages:
- English
- ISSNs:
- 1058-2916
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1738.840500
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File: