Preoperative Predictors of Death and Sustained Ventricular Tachycardia After Pulmonary Valve Replacement in Patients With Repaired Tetralogy of Fallot Enrolled in the INDICATOR Cohort. Issue 19 (6th November 2018)
- Record Type:
- Journal Article
- Title:
- Preoperative Predictors of Death and Sustained Ventricular Tachycardia After Pulmonary Valve Replacement in Patients With Repaired Tetralogy of Fallot Enrolled in the INDICATOR Cohort. Issue 19 (6th November 2018)
- Main Title:
- Preoperative Predictors of Death and Sustained Ventricular Tachycardia After Pulmonary Valve Replacement in Patients With Repaired Tetralogy of Fallot Enrolled in the INDICATOR Cohort
- Authors:
- Geva, Tal
Mulder, Barbara
Gauvreau, Kimberlee
Babu-Narayan, Sonya V.
Wald, Rachel M.
Hickey, Kelsey
Powell, Andrew J.
Gatzoulis, Michael A.
Valente, Anne Marie - Abstract:
- Abstract : Background: Risk factors for adverse clinical outcomes have been identified in patients with repaired tetralogy of Fallot before pulmonary valve replacement (PVR). However, pre-PVR predictors for post-PVR sustained ventricular tachycardia and death have not been identified. Methods: Patients with repaired tetralogy of Fallot enrolled in the INDICATOR cohort (International Multicenter TOF Registry), a 4-center international cohort study, who had a comprehensive preoperative evaluation and subsequently underwent PVR were included. Preprocedural clinical, ECG, cardiovascular magnetic resonance, and postoperative outcome data were analyzed. Cox proportional hazards multivariable regression analysis was used to evaluate factors associated with time from pre-PVR cardiovascular magnetic resonance until the primary outcome: death, aborted sudden cardiac death, or sustained ventricular tachycardia. Results: Of the 452 eligible patients (median age at PVR, 25.8 years), 36 (8%) reached the primary outcome (27 deaths, 2 resuscitated death, and 7 sustained ventricular tachycardia) at a median time after PVR of 6.5 years. Cox proportional hazards regression identified pre-PVR right ventricular ejection fraction <40% (hazard ratio, 2.39; 95% CI, 1.18–4.85; P =0.02), right ventricular mass-to-volume ratio ≥0.45 g/mL (hazard ratio, 4.08; 95% CI, 1.57–10.6; P =0.004), and age at PVR ≥28 years (hazard ratio, 3.10; 95% CI, 1.42–6.78; P =0.005) as outcome predictors. In a subgroupAbstract : Background: Risk factors for adverse clinical outcomes have been identified in patients with repaired tetralogy of Fallot before pulmonary valve replacement (PVR). However, pre-PVR predictors for post-PVR sustained ventricular tachycardia and death have not been identified. Methods: Patients with repaired tetralogy of Fallot enrolled in the INDICATOR cohort (International Multicenter TOF Registry), a 4-center international cohort study, who had a comprehensive preoperative evaluation and subsequently underwent PVR were included. Preprocedural clinical, ECG, cardiovascular magnetic resonance, and postoperative outcome data were analyzed. Cox proportional hazards multivariable regression analysis was used to evaluate factors associated with time from pre-PVR cardiovascular magnetic resonance until the primary outcome: death, aborted sudden cardiac death, or sustained ventricular tachycardia. Results: Of the 452 eligible patients (median age at PVR, 25.8 years), 36 (8%) reached the primary outcome (27 deaths, 2 resuscitated death, and 7 sustained ventricular tachycardia) at a median time after PVR of 6.5 years. Cox proportional hazards regression identified pre-PVR right ventricular ejection fraction <40% (hazard ratio, 2.39; 95% CI, 1.18–4.85; P =0.02), right ventricular mass-to-volume ratio ≥0.45 g/mL (hazard ratio, 4.08; 95% CI, 1.57–10.6; P =0.004), and age at PVR ≥28 years (hazard ratio, 3.10; 95% CI, 1.42–6.78; P =0.005) as outcome predictors. In a subgroup analysis of 230 patients with Doppler data, predicted right ventricular systolic pressure ≥40 mm Hg was associated with the primary outcome (hazard ratio, 3.42; 95% CI, 1.09–10.7; P =0.04). Preoperative predictors of a composite secondary outcome, postoperative arrhythmias and heart failure, included older age at PVR, pre-PVR atrial tachyarrhythmias, and a higher left ventricular end-systolic volume index. Conclusions: In this observational investigation of patients with repaired tetralogy of Fallot, an older age at PVR and pre-PVR right ventricular hypertrophy and dysfunction were predictive of a shorter time to postoperative death and sustained ventricular tachycardia. These findings may inform the timing of PVR if confirmed by prospective clinical trials. … (more)
- Is Part Of:
- Circulation. Volume 138:Issue 19(2018)
- Journal:
- Circulation
- Issue:
- Volume 138:Issue 19(2018)
- Issue Display:
- Volume 138, Issue 19 (2018)
- Year:
- 2018
- Volume:
- 138
- Issue:
- 19
- Issue Sort Value:
- 2018-0138-0019-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-11-06
- Subjects:
- hypertrophy, right ventricular -- pulmonary valve -- risk factors -- tachycardia, ventricular -- tetralogy of Fallot -- treatment outcome
Blood -- Circulation -- Periodicals
Cardiovascular system -- Periodicals
Cardiology -- Periodicals
Heart -- Diseases -- Periodicals
Blood Circulation
Cardiovascular System
Vascular Diseases
616.1 - Journal URLs:
- http://ovidsp.tx.ovid.com/sp-3.4.2a/ovidweb.cgi?&S=HFFJFPCLPODDKOLGNCALDCMCIACKAA00&Browse=Toc+Children%7cNO%7cS.sh.1384_1326796138_84.1384_1326796138_96.1384_1326796138_97%7c66%7c50 ↗
http://www.circulationaha.org ↗
http://circ.ahajournals.org/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1161/CIRCULATIONAHA.118.034740 ↗
- Languages:
- English
- ISSNs:
- 0009-7322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3265.200000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11208.xml