A carbon CT system: how to obtain accurate stopping power ratio using a Bragg peak reduction technique. (31st January 2018)
- Record Type:
- Journal Article
- Title:
- A carbon CT system: how to obtain accurate stopping power ratio using a Bragg peak reduction technique. (31st January 2018)
- Main Title:
- A carbon CT system: how to obtain accurate stopping power ratio using a Bragg peak reduction technique
- Authors:
- Lee, Sung Hyun
Sunaguchi, Naoki
Hirano, Yoshiyuki
Kano, Yosuke
Liu, Chang
Torikoshi, Masami
Ohno, Tatsuya
Nakano, Takashi
Kanai, Tatsuaki - Abstract:
- Abstract: In this study, we investigate the performance of the Gunma University Heavy Ion Medical Center's ion computed tomography (CT) system, which measures the residual range of a carbon-ion beam using a fluoroscopy screen, a charge-coupled-device camera, and a moving wedge absorber and collects CT reconstruction images from each projection angle. Each 2D image was obtained by changing the polymethyl methacrylate (PMMA) thickness, such that all images for one projection could be expressed as the depth distribution in PMMA. The residual range as a function of PMMA depth was related to the range in water through a calibration factor, which was determined by comparing the PMMA-equivalent thickness measured by the ion CT system to the water-equivalent thickness measured by a water column. Aluminium, graphite, PMMA, and five biological phantoms were placed in a sample holder, and the residual range for each was quantified simultaneously. A novel method of CT reconstruction to correct for the angular deflection of incident carbon ions in the heterogeneous region utilising the Bragg peak reduction (BPR) is also introduced in this paper, and its performance is compared with other methods present in the literature such as the decomposition and differential methods. Stopping power ratio values derived with the BPR method from carbon-ion CT images matched closely with the true water-equivalent length values obtained from the validation slab experiment.
- Is Part Of:
- Physics in medicine & biology. Volume 63:Number 3(2018:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 63:Number 3(2018:Feb.)
- Issue Display:
- Volume 63, Issue 3 (2018)
- Year:
- 2018
- Volume:
- 63
- Issue:
- 3
- Issue Sort Value:
- 2018-0063-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-01-31
- Subjects:
- ion beam therapy -- carbon CT -- angular deflection -- stopping power ratio
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aaa453 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11207.xml