Integrated self-validating thermocouples with a reference temperature up to 1329 °C. (31st August 2018)
- Record Type:
- Journal Article
- Title:
- Integrated self-validating thermocouples with a reference temperature up to 1329 °C. (31st August 2018)
- Main Title:
- Integrated self-validating thermocouples with a reference temperature up to 1329 °C
- Authors:
- Tucker, Declan
Andreu, Aurik
Elliott, Claire
Ford, Trevor
Neagu, Marius
Machin, Graham
Pearce, Jonathan - Abstract:
- Abstract: Thermoelectric instability, or calibration drift, is a major problem for users of thermocouples at high temperature. NPL, in collaboration with CCPI Europe, AFRC and ICPE-CA/BRML-INM has designed, made and industrially tested Type S thermocouples with integrated temperature fixed-point cells. These in situ, self-validating thermocouples (denoted 'inseva') have the same external dimensions as conventional industrial thermocouples (the recrystallised alumina sheath has an outer diameter 7 of mm). The device can be used to detect the melting and/or freezing temperature of the integrated temperature fixed-point ingot, which enables a self-validation to be performed whilst in situ . During the testing, three different reference ingots were used in the cells, namely: copper (1084 °C), cobalt-carbon (1324 °C) and nickel-carbon (1329 °C). The metrological performance for two iterations of the design are presented, with an emphasis on the ability of the inseva thermocouples to indicate their own thermoelectric stability. A measurement uncertainty budget is also given for the case of a Ni–C inseva thermocouple. This paper demonstrates that inseva thermocouples can be successfully validated during industrial processes through the observation of the melting plateau, as well as their robustness over time in industrial conditions. A key finding is that the Ni–C eutectic alloy is much more robust than the Co–C eutectic alloy for the used type of graphite crucible, making the Ni–CAbstract: Thermoelectric instability, or calibration drift, is a major problem for users of thermocouples at high temperature. NPL, in collaboration with CCPI Europe, AFRC and ICPE-CA/BRML-INM has designed, made and industrially tested Type S thermocouples with integrated temperature fixed-point cells. These in situ, self-validating thermocouples (denoted 'inseva') have the same external dimensions as conventional industrial thermocouples (the recrystallised alumina sheath has an outer diameter 7 of mm). The device can be used to detect the melting and/or freezing temperature of the integrated temperature fixed-point ingot, which enables a self-validation to be performed whilst in situ . During the testing, three different reference ingots were used in the cells, namely: copper (1084 °C), cobalt-carbon (1324 °C) and nickel-carbon (1329 °C). The metrological performance for two iterations of the design are presented, with an emphasis on the ability of the inseva thermocouples to indicate their own thermoelectric stability. A measurement uncertainty budget is also given for the case of a Ni–C inseva thermocouple. This paper demonstrates that inseva thermocouples can be successfully validated during industrial processes through the observation of the melting plateau, as well as their robustness over time in industrial conditions. A key finding is that the Ni–C eutectic alloy is much more robust than the Co–C eutectic alloy for the used type of graphite crucible, making the Ni–C inseva thermocouple more suitable for industrial applications, and a good alternative. … (more)
- Is Part Of:
- Measurement science & technology. Volume 29:Number 10(2018:Oct.)
- Journal:
- Measurement science & technology
- Issue:
- Volume 29:Number 10(2018:Oct.)
- Issue Display:
- Volume 29, Issue 10 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 10
- Issue Sort Value:
- 2018-0029-0010-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08-31
- Subjects:
- self-validating -- thermocouple -- integrated -- calibration -- htfp -- inseva
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/aad8a8 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11195.xml