Non-linear fitting-based phasor measurement method for PMU calibrator. (March 2019)
- Record Type:
- Journal Article
- Title:
- Non-linear fitting-based phasor measurement method for PMU calibrator. (March 2019)
- Main Title:
- Non-linear fitting-based phasor measurement method for PMU calibrator
- Authors:
- Liu, Hao
Xu, Sudi
Bi, Tianshu
Martin, Kenneth E.
Qian, Cheng
Wang, Lu - Abstract:
- Highlights: A non-linear fitting-based phasor measurement method for PMU calibrator is proposed. Parameters setting methods are proposed to ensure uniqueness of the solution. White noise restraining methods are proposed to further improve accuracy. A PMU calibrator is developed based on the proposed method. Testing results show that he PMU calibrator can provide valid test references. Abstract: With the increasing penetration of renewable energies, phasor measurement units (PMUs) play increasingly important roles in security control and mechanism studies for power systems. The testing and calibration of PMUs are key to their effectiveness in a power system; therefore, providing valid test reference values with sufficient precision under steady-state and dynamic conditions is critical. This paper proposes a non-linear fitting-based phasor measurement method for a PMU calibrator to provide reference measurements. Two universal phasor-fitting models are built to represent different signals in PMU steady and dynamic testing. An objective function is presented, which obtains the minimum value of the sum of squares of a non-linear real-valued function based on phasor-fitting models. The methods to set the initial points and bound constraints of the parameters to be fitted are stated to make the objective function convex. An iterative technique, finding the local minimizer of the built objective function in the restricted region, is proposed to calculate the phasor, frequency, andHighlights: A non-linear fitting-based phasor measurement method for PMU calibrator is proposed. Parameters setting methods are proposed to ensure uniqueness of the solution. White noise restraining methods are proposed to further improve accuracy. A PMU calibrator is developed based on the proposed method. Testing results show that he PMU calibrator can provide valid test references. Abstract: With the increasing penetration of renewable energies, phasor measurement units (PMUs) play increasingly important roles in security control and mechanism studies for power systems. The testing and calibration of PMUs are key to their effectiveness in a power system; therefore, providing valid test reference values with sufficient precision under steady-state and dynamic conditions is critical. This paper proposes a non-linear fitting-based phasor measurement method for a PMU calibrator to provide reference measurements. Two universal phasor-fitting models are built to represent different signals in PMU steady and dynamic testing. An objective function is presented, which obtains the minimum value of the sum of squares of a non-linear real-valued function based on phasor-fitting models. The methods to set the initial points and bound constraints of the parameters to be fitted are stated to make the objective function convex. An iterative technique, finding the local minimizer of the built objective function in the restricted region, is proposed to calculate the phasor, frequency, and rate of change of frequency (ROCOF). A white noise restraining method is proposed to further improve measurement accuracy. Then, the proposed method is implemented into hardware to develop a real PMU calibrator. To verify the accuracy of the PMU calibrator, simulations and experimental testing are carried out. Results show that the effectiveness of the PMU calibrator can meet calibration requirements under typical static and dynamic conditions of power systems with high penetration of renewable energies. The developed PMU calibrator can thus be used to calibrate PMUs. … (more)
- Is Part Of:
- International journal of electrical power & energy systems. Volume 106(2019)
- Journal:
- International journal of electrical power & energy systems
- Issue:
- Volume 106(2019)
- Issue Display:
- Volume 106, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 106
- Issue:
- 2019
- Issue Sort Value:
- 2019-0106-2019-0000
- Page Start:
- 585
- Page End:
- 597
- Publication Date:
- 2019-03
- Subjects:
- Phasor measurement units -- PMU calibrator -- Phasor measurement method -- Non-linear fitting algorithm
Electrical engineering -- Periodicals
Electric power systems -- Periodicals
Électrotechnique -- Périodiques
Réseaux électriques (Énergie) -- Périodiques
Electric power systems
Electrical engineering
Periodicals
621.3 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01420615 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijepes.2018.10.022 ↗
- Languages:
- English
- ISSNs:
- 0142-0615
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.220000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11191.xml