The impact of ambient humidity on the evaporation and dispersion of exhaled breathing droplets: A numerical investigation. (January 2018)
- Record Type:
- Journal Article
- Title:
- The impact of ambient humidity on the evaporation and dispersion of exhaled breathing droplets: A numerical investigation. (January 2018)
- Main Title:
- The impact of ambient humidity on the evaporation and dispersion of exhaled breathing droplets: A numerical investigation
- Authors:
- Ji, Yichen
Qian, Hua
Ye, Jin
Zheng, Xiaohong - Abstract:
- Abstract: The impact of ambient relative humidity (RH) and airflow patterns on the evaporation and dispersion of infectious droplets exhaled from an infector was studied by the computational fluid dynamics (CFD) method. The DPM (discrete phase model) was employed to calculate the two phase flow, i.e. droplets and air. The model is validated by experimental and simulation results in literature. Pure water droplets with different diameters (every 10 µm between 10 µm and 100 µm) are exhaled from an infector in different ventilation systems, i.e. mixing and displacement with different RHs (0, 30%, 60% and 90%). The diameter variation, spatial distribution and spreading distance of droplets are simulated and compared. Results showed that evaporation of droplets under mixing ventilation is quicker than it under displacement ventilation due to accelerated heat and mass transfer between droplets and air by turbulence. However, the dried out time for small droplets (e.g. 10 µm) are extremely short, whatever the ventilation system is. Slow air velocity in displacement system or high RH environment may lower the evaporation speed of middle size droplets (e.g. 50 µm) and accelerate the dropping of large size droplets (e.g. 200 µm). For 100 µm droplets, they evaporate fast with low RHs while deposit fast with high RHs. Most droplets concentrate within ± 0.5 m of the person's mouth before they become droplet nuclei or fall onto the ground. This model may offer some suggestions inAbstract: The impact of ambient relative humidity (RH) and airflow patterns on the evaporation and dispersion of infectious droplets exhaled from an infector was studied by the computational fluid dynamics (CFD) method. The DPM (discrete phase model) was employed to calculate the two phase flow, i.e. droplets and air. The model is validated by experimental and simulation results in literature. Pure water droplets with different diameters (every 10 µm between 10 µm and 100 µm) are exhaled from an infector in different ventilation systems, i.e. mixing and displacement with different RHs (0, 30%, 60% and 90%). The diameter variation, spatial distribution and spreading distance of droplets are simulated and compared. Results showed that evaporation of droplets under mixing ventilation is quicker than it under displacement ventilation due to accelerated heat and mass transfer between droplets and air by turbulence. However, the dried out time for small droplets (e.g. 10 µm) are extremely short, whatever the ventilation system is. Slow air velocity in displacement system or high RH environment may lower the evaporation speed of middle size droplets (e.g. 50 µm) and accelerate the dropping of large size droplets (e.g. 200 µm). For 100 µm droplets, they evaporate fast with low RHs while deposit fast with high RHs. Most droplets concentrate within ± 0.5 m of the person's mouth before they become droplet nuclei or fall onto the ground. This model may offer some suggestions in identifying favorable humidity-control ways to prevent the short-range infection transmission. Highlights: Effects of RH on droplets evaporation distinguishes from ventilation systems. Evaporation speed of medium droplets may be lowered in displacement system or high RH. Falling speed of large droplets may be accelerated in displacement system or high RH. … (more)
- Is Part Of:
- Journal of aerosol science. Volume 115(2018)
- Journal:
- Journal of aerosol science
- Issue:
- Volume 115(2018)
- Issue Display:
- Volume 115, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 115
- Issue:
- 2018
- Issue Sort Value:
- 2018-0115-2018-0000
- Page Start:
- 164
- Page End:
- 172
- Publication Date:
- 2018-01
- Subjects:
- Droplets -- Evaporation -- Dispersion -- Ventilation system -- Relative humidity (RH)
Aerosols -- Periodicals
Aerosols -- Periodicals
Aérosols -- Périodiques
541.34515 - Journal URLs:
- http://www.journals.elsevier.com/journal-of-aerosol-science/ ↗
http://www.sciencedirect.com/science/journal/00218502 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jaerosci.2017.10.009 ↗
- Languages:
- English
- ISSNs:
- 0021-8502
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4919.060000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11202.xml