Effectiveness of single‐ vs dual‐coil implantable defibrillator leads: An observational analysis from the SIMPLE study. (22nd April 2019)
- Record Type:
- Journal Article
- Title:
- Effectiveness of single‐ vs dual‐coil implantable defibrillator leads: An observational analysis from the SIMPLE study. (22nd April 2019)
- Main Title:
- Effectiveness of single‐ vs dual‐coil implantable defibrillator leads: An observational analysis from the SIMPLE study
- Authors:
- Neuzner, Jörg
Hohnloser, Stefan H.
Kutyifa, Valentina
Glikson, Michael
Dietze, Thomas
Mabo, Philippe
Vinolas, Xavier
Kautzner, Josef
O'Hara, Gilles
Lawo, Thomas
Brachmann, Johannes
VanErven, Liselot
Gadler, Fredrik
Appl, Ursula
Wang, Jia
Connolly, Stuart J.
Healey, Jeff S. - Abstract:
- Abstract: Introduction: Dual‐coil leads (DC‐leads) were the standard of choice since the first nonthoracotomy implantable cardioverter/defibrillator (ICD). We used contemporary data to determine if DC‐leads offer any advantage over single‐coil leads (SC‐leads), in terms of defibrillation efficacy, safety, clinical outcome, and complication rates. Methods and Results: In the Shockless IMPLant Evaluation study, 2500 patients received a first implanted ICD and were randomized to implantation with or without defibrillation testing. Two thousand and four hundred seventy‐five patients received SC‐coil or DC‐coil leads (SC‐leads in 1025/2475 patients; 41.4%). In patients who underwent defibrillation testing (n = 1204), patients with both lead types were equally likely to achieve an adequate defibrillation safety margin (88.8% vs 91.2%; P = 0.16). There was no overall effect of lead type on the primary study endpoint of "failed appropriate shock or arrhythmic death" (adjusted HR 1.18; 95% CI, 0.86‐1.62; P = 0.300), and on all‐cause mortality (SC‐leads: 5.34%/year; DC‐leads: 5.48%/year; adjusted HR 1.16; 95% CI, 0.94‐1.43; P = 0.168). However, among patients without prior heart failure (HF), and SC‐leads had a significantly higher risk of failed appropriate shock or arrhythmic death (adjusted HR 7.02; 95% CI, 2.41‐20.5). There were no differences in complication rates. Conclusion: In this nonrandomized evaluation, there was no overall difference in defibrillation efficacy, safety,Abstract: Introduction: Dual‐coil leads (DC‐leads) were the standard of choice since the first nonthoracotomy implantable cardioverter/defibrillator (ICD). We used contemporary data to determine if DC‐leads offer any advantage over single‐coil leads (SC‐leads), in terms of defibrillation efficacy, safety, clinical outcome, and complication rates. Methods and Results: In the Shockless IMPLant Evaluation study, 2500 patients received a first implanted ICD and were randomized to implantation with or without defibrillation testing. Two thousand and four hundred seventy‐five patients received SC‐coil or DC‐coil leads (SC‐leads in 1025/2475 patients; 41.4%). In patients who underwent defibrillation testing (n = 1204), patients with both lead types were equally likely to achieve an adequate defibrillation safety margin (88.8% vs 91.2%; P = 0.16). There was no overall effect of lead type on the primary study endpoint of "failed appropriate shock or arrhythmic death" (adjusted HR 1.18; 95% CI, 0.86‐1.62; P = 0.300), and on all‐cause mortality (SC‐leads: 5.34%/year; DC‐leads: 5.48%/year; adjusted HR 1.16; 95% CI, 0.94‐1.43; P = 0.168). However, among patients without prior heart failure (HF), and SC‐leads had a significantly higher risk of failed appropriate shock or arrhythmic death (adjusted HR 7.02; 95% CI, 2.41‐20.5). There were no differences in complication rates. Conclusion: In this nonrandomized evaluation, there was no overall difference in defibrillation efficacy, safety, outcome, and complication rates between SC‐leads and DC‐leads. However, DC‐leads were associated with a reduction in the composite of failed appropriate shock or arrhythmic death in the subgroup of non‐HF patients. Considering riskier future lead extraction with DC‐leads, SC‐leads appears to be preferable in the majority of patients. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 30:Number 7(2019)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 30:Number 7(2019)
- Issue Display:
- Volume 30, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 30
- Issue:
- 7
- Issue Sort Value:
- 2019-0030-0007-0000
- Page Start:
- 1078
- Page End:
- 1085
- Publication Date:
- 2019-04-22
- Subjects:
- all‐cause mortality -- arrhythmic death -- defibrillation shock efficacy -- failed appropriate shocks -- implantable cardioverter‐defibrillator -- intraoperative defibrillation testing -- single‐coil and dual‐coil leads
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.13943 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11170.xml