Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars. (4th July 2019)
- Record Type:
- Journal Article
- Title:
- Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars. (4th July 2019)
- Main Title:
- Repeatability and Reproducibility of Slit Lamp, Optical Coherence Tomography, and Scheimpflug Measurements of Corneal Scars
- Authors:
- Das, Manoranjan
Menda, Shivali A.
Panigrahi, Arun K.
Venkatesh Prajna, N.
Yen, Michael
Tsang, Betty
Kumar, Alisha
Rose-Nussbaumer, Jennifer
Acharya, Nisha R.
McCulloch, Charles E.
Lietman, Thomas M.
McLeod, Stephen D.
Keenan, Jeremy D. - Abstract:
- ABSTRACT: Purpose : To determine the repeatability and reproducibility of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug photography for several measurements of corneal scars, including scar size, scar depth, and corneal thickness. Methods : A series of patients treated for fungal keratitis at a tertiary eye care center in South India were recalled two years after successful treatment. Eyes with corneal scars had a slit lamp examination performed by two ophthalmologists masked to the other's examination. For AS-OCT and Scheimpflug photography, each eye had two scans taken by one technician and a third scan taken by a separate technician. Scar measurements were subsequently assessed from AS-OCT images by three graders masked to each other's results. Repeatability and reproducibility were assessed by calculating the intra-class correlation coefficient (ICC) from mixed effects linear regression models. Results : Fifty eyes had all measurements taken. The corneal scar size, measured as the geometric mean of the two longest perpendicular meridians, ranged from 0.8 to 5.4 (mean 2.8 mm, 95%CI 2.6 to 3.1). Scar size measurements taken by two separate individuals were most reproducible when the border of the scar was traced from the OCT (ICC 0.90, 95%CI 0.86 to 0.94), and least repeatable when assessed from slit lamp examination (ICC 0.80, 95%CI 0.70 to 0.90). Conclusions : AS-OCT and Scheimpflug imaging of corneal scars produced measurements with acceptableABSTRACT: Purpose : To determine the repeatability and reproducibility of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug photography for several measurements of corneal scars, including scar size, scar depth, and corneal thickness. Methods : A series of patients treated for fungal keratitis at a tertiary eye care center in South India were recalled two years after successful treatment. Eyes with corneal scars had a slit lamp examination performed by two ophthalmologists masked to the other's examination. For AS-OCT and Scheimpflug photography, each eye had two scans taken by one technician and a third scan taken by a separate technician. Scar measurements were subsequently assessed from AS-OCT images by three graders masked to each other's results. Repeatability and reproducibility were assessed by calculating the intra-class correlation coefficient (ICC) from mixed effects linear regression models. Results : Fifty eyes had all measurements taken. The corneal scar size, measured as the geometric mean of the two longest perpendicular meridians, ranged from 0.8 to 5.4 (mean 2.8 mm, 95%CI 2.6 to 3.1). Scar size measurements taken by two separate individuals were most reproducible when the border of the scar was traced from the OCT (ICC 0.90, 95%CI 0.86 to 0.94), and least repeatable when assessed from slit lamp examination (ICC 0.80, 95%CI 0.70 to 0.90). Conclusions : AS-OCT and Scheimpflug imaging of corneal scars produced measurements with acceptable reproducibility that could be useful as cornea-specific outcomes for clinical trials. … (more)
- Is Part Of:
- Ophthalmic epidemiology. Volume 26:Number 4(2019)
- Journal:
- Ophthalmic epidemiology
- Issue:
- Volume 26:Number 4(2019)
- Issue Display:
- Volume 26, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 26
- Issue:
- 4
- Issue Sort Value:
- 2019-0026-0004-0000
- Page Start:
- 251
- Page End:
- 256
- Publication Date:
- 2019-07-04
- Subjects:
- Corneal opacity -- corneal ulcer -- tomography -- optical coherence -- corneal topography -- reliability
Blindness -- Prevention -- Periodicals
Eye -- Diseases -- Epidemiology -- Periodicals
Ophthalmology -- Periodicals
614.5997 - Journal URLs:
- http://informahealthcare.com/loi/ope ↗
http://informahealthcare.com ↗
http://www.tandf.co.uk/journals/titles/09286586.asp ↗ - DOI:
- 10.1080/09286586.2019.1600199 ↗
- Languages:
- English
- ISSNs:
- 0928-6586
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6270.880000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11172.xml