Online 4D ultrasound guidance for real‐time motion compensation by MLC tracking. Issue 10 (28th September 2016)
- Record Type:
- Journal Article
- Title:
- Online 4D ultrasound guidance for real‐time motion compensation by MLC tracking. Issue 10 (28th September 2016)
- Main Title:
- Online 4D ultrasound guidance for real‐time motion compensation by MLC tracking
- Authors:
- Ipsen, Svenja
Bruder, Ralf
O'Brien, Rick
Keall, Paul J.
Schweikard, Achim
Poulsen, Per R. - Abstract:
- Abstract : Purpose: With the trend in radiotherapy moving toward dose escalation and hypofractionation, the need for highly accurate targeting increases. While MLC tracking is already being successfully used for motion compensation of moving targets in the prostate, current real‐time target localization methods rely on repeated x‐ray imaging and implanted fiducial markers or electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging can yield volumetric data in real‐time (3D + time = 4D) without ionizing radiation. The authors report the first results of combining these promising techniques—online 4D ultrasound guidance and MLC tracking—in a phantom. Methods: A software framework for real‐time target localization was installed directly on a 4D ultrasound station and used to detect a 2 mm spherical lead marker inside a water tank. The lead marker was rigidly attached to a motion stage programmed to reproduce nine characteristic tumor trajectories chosen from large databases (five prostate, four lung). The 3D marker position detected by ultrasound was transferred to a computer program for MLC tracking at a rate of 21.3 Hz and used for real‐time MLC aperture adaption on a conventional linear accelerator. The tracking system latency was measured using sinusoidal trajectories and compensated for by applying a kernel density prediction algorithm for the lung traces. To measure geometric accuracy, static anterior and lateral conformalAbstract : Purpose: With the trend in radiotherapy moving toward dose escalation and hypofractionation, the need for highly accurate targeting increases. While MLC tracking is already being successfully used for motion compensation of moving targets in the prostate, current real‐time target localization methods rely on repeated x‐ray imaging and implanted fiducial markers or electromagnetic transponders rather than direct target visualization. In contrast, ultrasound imaging can yield volumetric data in real‐time (3D + time = 4D) without ionizing radiation. The authors report the first results of combining these promising techniques—online 4D ultrasound guidance and MLC tracking—in a phantom. Methods: A software framework for real‐time target localization was installed directly on a 4D ultrasound station and used to detect a 2 mm spherical lead marker inside a water tank. The lead marker was rigidly attached to a motion stage programmed to reproduce nine characteristic tumor trajectories chosen from large databases (five prostate, four lung). The 3D marker position detected by ultrasound was transferred to a computer program for MLC tracking at a rate of 21.3 Hz and used for real‐time MLC aperture adaption on a conventional linear accelerator. The tracking system latency was measured using sinusoidal trajectories and compensated for by applying a kernel density prediction algorithm for the lung traces. To measure geometric accuracy, static anterior and lateral conformal fields as well as a 358° arc with a 10 cm circular aperture were delivered for each trajectory. The two‐dimensional (2D) geometric tracking error was measured as the difference between marker position and MLC aperture center in continuously acquired portal images. For dosimetric evaluation, VMAT treatment plans with high and low modulation were delivered to a biplanar diode array dosimeter using the same trajectories. Dose measurements with and without MLC tracking were compared to a static reference dose using 3%/3 mm and 2%/2 mm γ ‐tests. Results: The overall tracking system latency was 172 ms. The mean 2D root‐mean‐square tracking error was 1.03 mm (0.80 mm prostate, 1.31 mm lung). MLC tracking improved the dose delivery in all cases with an overall reduction in the γ ‐failure rate of 91.2% (3%/3 mm) and 89.9% (2%/2 mm) compared to no motion compensation. Low modulation VMAT plans had no (3%/3 mm) or minimal (2%/2 mm) residual γ ‐failures while tracking reduced the γ ‐failure rate from 17.4% to 2.8% (3%/3 mm) and from 33.9% to 6.5% (2%/2 mm) for plans with high modulation. Conclusions: Real‐time 4D ultrasound tracking was successfully integrated with online MLC tracking for the first time. The developed framework showed an accuracy and latency comparable with other MLC tracking methods while holding the potential to measure and adapt to target motion, including rotation and deformation, noninvasively. … (more)
- Is Part Of:
- Medical physics. Volume 43:Issue 10(2016)
- Journal:
- Medical physics
- Issue:
- Volume 43:Issue 10(2016)
- Issue Display:
- Volume 43, Issue 10 (2016)
- Year:
- 2016
- Volume:
- 43
- Issue:
- 10
- Issue Sort Value:
- 2016-0043-0010-0000
- Page Start:
- 5695
- Page End:
- 5704
- Publication Date:
- 2016-09-28
- Subjects:
- biomedical ultrasonics -- dosimetry -- lung -- phantoms -- radiation therapy -- tumours
Ultrasonographic imaging -- Dosimetry/exposure assessment -- Therapeutic applications
Diagnosis using ultrasonic, sonic or infrasonic waves -- Radiation therapy -- Biological material, e.g. blood, urine; Haemocytometers -- Scintigraphy
ultrasound -- multileaf collimator -- real‐time motion compensation -- image guidance
Multileaf collimators -- Ultrasonography -- Lungs -- Dosimetry -- Tracking devices -- Cancer -- Motion compensation -- Real time information delivery
Medical physics -- Periodicals
Medical physics
Geneeskunde
Natuurkunde
Toepassingen
Biophysics
Periodicals
Periodicals
Electronic journals
610.153 - Journal URLs:
- http://scitation.aip.org/content/aapm/journal/medphys ↗
https://aapm.onlinelibrary.wiley.com/journal/24734209 ↗
http://www.aip.org/ ↗ - DOI:
- 10.1118/1.4962932 ↗
- Languages:
- English
- ISSNs:
- 0094-2405
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5531.130000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11154.xml