The wearable cardioverter defibrillator as a bridge to reimplantation in patients with ICD or CRT-D-related infections. Issue 1 (December 2017)
- Record Type:
- Journal Article
- Title:
- The wearable cardioverter defibrillator as a bridge to reimplantation in patients with ICD or CRT-D-related infections. Issue 1 (December 2017)
- Main Title:
- The wearable cardioverter defibrillator as a bridge to reimplantation in patients with ICD or CRT-D-related infections
- Authors:
- Castro, L.
Pecha, S.
Linder, M.
Vogler, J.
Gosau, N.
Meyer, C.
Willems, S.
Reichenspurner, H.
Hakmi, S. - Abstract:
- Abstract Background The approach to treat device infection in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) is a challenging procedure. Optimal treatment is complete extraction of the infected device. To protect these patients from sudden cardiac arrest while waiting for reimplantation and to avoid recurrent infection, a wearable cardioverter defibrillator (WCD) seems to be a valuable solution. Therefore, we investigated the management and outcome of patients with ICD or CRT-D infections using the WCD as a bridge to re-implantation after lead extraction procedures. Methods We conducted a retrospective study on consecutive patients who underwent ICD or CRT-D removal due to device-related local or systemic infections. All patients were prescribed a WCD at our center between 01/2012 and 10/2015. All patients returned to our outpatient clinic for regular ICD or CRT-D monitoring initially 1 and 3 months after reimplantation followed by 6-months intervals. Results Twenty-one patients (mean age 65.0 ± 8.0 years, male 76.2%) were included in the study. Complete lead extraction was achieved in all patients. While waiting for reimplantation one patient experienced a symptomatic episode of sustained ventricular tachycardia. This episode was converted successfully into sinus rhythm by a single 150 J shock. Mean follow-up time 392 ± 206 days, showing survival rate of 100% and freedom from reinfection in all patients.Abstract Background The approach to treat device infection in patients with implantable cardioverter defibrillator (ICD) or cardiac resynchronization therapy defibrillator (CRT-D) is a challenging procedure. Optimal treatment is complete extraction of the infected device. To protect these patients from sudden cardiac arrest while waiting for reimplantation and to avoid recurrent infection, a wearable cardioverter defibrillator (WCD) seems to be a valuable solution. Therefore, we investigated the management and outcome of patients with ICD or CRT-D infections using the WCD as a bridge to re-implantation after lead extraction procedures. Methods We conducted a retrospective study on consecutive patients who underwent ICD or CRT-D removal due to device-related local or systemic infections. All patients were prescribed a WCD at our center between 01/2012 and 10/2015. All patients returned to our outpatient clinic for regular ICD or CRT-D monitoring initially 1 and 3 months after reimplantation followed by 6-months intervals. Results Twenty-one patients (mean age 65.0 ± 8.0 years, male 76.2%) were included in the study. Complete lead extraction was achieved in all patients. While waiting for reimplantation one patient experienced a symptomatic episode of sustained ventricular tachycardia. This episode was converted successfully into sinus rhythm by a single 150 J shock. Mean follow-up time 392 ± 206 days, showing survival rate of 100% and freedom from reinfection in all patients. Conclusion The WCD seems to be a valuable bridging option for patients with ICD or CRT-D infections, showing no recurrent device infection. … (more)
- Is Part Of:
- Journal of cardiothoracic surgery. Volume 12:Issue 1(2017)
- Journal:
- Journal of cardiothoracic surgery
- Issue:
- Volume 12:Issue 1(2017)
- Issue Display:
- Volume 12, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 12
- Issue:
- 1
- Issue Sort Value:
- 2017-0012-0001-0000
- Page Start:
- 1
- Page End:
- 6
- Publication Date:
- 2017-12
- Subjects:
- Wearable cardioverter defibrillator -- CIED-infection -- ICD infection -- Sudden cardiac arrest -- Lead/ device extraction -- Ventricular tachycardia
Chest -- Surgery -- Periodicals
Heart -- Surgery -- Periodicals
617.54005 - Journal URLs:
- http://pubmedcentral.com/tocrender.fcgi?journal=406&action=archive ↗
http://www.cardiothoracicsurgery.org/ ↗
http://link.springer.com/ ↗ - DOI:
- 10.1186/s13019-017-0669-2 ↗
- Languages:
- English
- ISSNs:
- 1749-8090
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11151.xml