Revisiting the frequency domain: the multiple and partial coherence of cerebral blood flow velocity in the assessment of dynamic cerebral autoregulation. (31st May 2016)
- Record Type:
- Journal Article
- Title:
- Revisiting the frequency domain: the multiple and partial coherence of cerebral blood flow velocity in the assessment of dynamic cerebral autoregulation. (31st May 2016)
- Main Title:
- Revisiting the frequency domain: the multiple and partial coherence of cerebral blood flow velocity in the assessment of dynamic cerebral autoregulation
- Authors:
- Katsogridakis, Emmanuel
Simpson, David M
Bush, Glen
Fan, Lingke
Birch, Anthony A
Allen, Robert
Potter, John F
Panerai, Ronney B - Abstract:
- Abstract: Despite advances in modelling dynamic autoregulation, only part of the variability of cerebral blood flow velocity (CBFV) in the low frequency range has been explained. We investigate whether a multivariate representation can be used for this purpose. Pseudorandom sequences were used to inflate thigh cuffs and to administer 5% CO2 . Multiple and partial coherence were estimated, using arterial blood pressure (ABP), end-tidal CO2 (EtCO2 ) and resistance area product as input and CBFV as output variables. The inclusion of second and third input variables increased the amount of CBFV variability that can be accounted for ( p < 10 −4 in both cases). Partial coherence estimates in the low frequency range (<0.07 Hz) were not influenced by the use of thigh cuffs, but CO2 administration had a statistically significant effect ( p < 10 −4 in all cases). We conclude that the inclusion of additional inputs of a priori known physiological significance can help account for a greater amount of CBFV variability and may represent a viable alternative to more conventional non-linear modelling. The results of partial coherence analysis suggest that dynamic autoregulation and CO2 reactivity are likely to be the result of different physiological mechanisms.
- Is Part Of:
- Physiological measurement. Volume 37:Number 7(2016:Jul.)
- Journal:
- Physiological measurement
- Issue:
- Volume 37:Number 7(2016:Jul.)
- Issue Display:
- Volume 37, Issue 7 (2016)
- Year:
- 2016
- Volume:
- 37
- Issue:
- 7
- Issue Sort Value:
- 2016-0037-0007-0000
- Page Start:
- 1056
- Page End:
- 1073
- Publication Date:
- 2016-05-31
- Subjects:
- pseudorandom binary sequences -- thigh cuffs -- end-tidal CO2 -- cerebral autoregulation
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/0967-3334/37/7/1056 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11123.xml