Diagnosing lactose malabsorption in children: difficulties in interpreting hydrogen breath test results. (2nd March 2016)
- Record Type:
- Journal Article
- Title:
- Diagnosing lactose malabsorption in children: difficulties in interpreting hydrogen breath test results. (2nd March 2016)
- Main Title:
- Diagnosing lactose malabsorption in children: difficulties in interpreting hydrogen breath test results
- Authors:
- Ruzsanyi, Veronika
Heinz-Erian, Peter
Entenmann, Andreas
Karall, Daniela
Müller, Thomas
Schimkowitsch, Alexander
Amann, Anton
Scholl-Bürgi, Sabine - Abstract:
- Abstract: Lactose malabsorption (LM) is caused by insufficient enzymatic degradation of the disaccharide by intestinal lactase. Although hydrogen (H2 ) breath tests (HBTs) are routinely applied to diagnose LM, false-negative results are not uncommon. Thirty-two pediatric patients (19 females, 13 males) were included in this prospective study. After oral lactose administration (1 g kg −1 bodyweight to a maximum of 25 g), breath H2 was measured by electrochemical detection. HBT was considered positive if H2 concentration exceeded an increase of ⩾20 ppm from baseline. In addition to H2, exhaled methane (CH4 ), blood glucose concentrations and clinical symptoms (flatulence, abdominal pain, diarrhea) were monitored. A positive HBT indicating LM was found in 12/32 (37.5%) patients. Only five (41.7%, 5/12) of these had clinical symptoms during HBT indicating lactose intolerance (LI). Decreased blood glucose concentration increments (⩽20 mg dL −1 (⩽1.1 mmol L −1 )) were found in 3/5 of these patients. CH4 concentrations ⩾10 ppm at any time during the test were observed in 5/32 (15.6%) patients and in 9/32 (28.1%) between 1 ppm and 9 ppm above baseline after lactose ingestion. In patients with positive HBT 10/12 (83.3%) showed elevated CH4 (>1 ppm) above baseline in breath gas, whereas in patients with negative HBT this figure was only 4/17 (23.5%). In addition to determining H2 in exhaled air, documentation of clinical symptoms, measurement of blood glucose and breath CH4Abstract: Lactose malabsorption (LM) is caused by insufficient enzymatic degradation of the disaccharide by intestinal lactase. Although hydrogen (H2 ) breath tests (HBTs) are routinely applied to diagnose LM, false-negative results are not uncommon. Thirty-two pediatric patients (19 females, 13 males) were included in this prospective study. After oral lactose administration (1 g kg −1 bodyweight to a maximum of 25 g), breath H2 was measured by electrochemical detection. HBT was considered positive if H2 concentration exceeded an increase of ⩾20 ppm from baseline. In addition to H2, exhaled methane (CH4 ), blood glucose concentrations and clinical symptoms (flatulence, abdominal pain, diarrhea) were monitored. A positive HBT indicating LM was found in 12/32 (37.5%) patients. Only five (41.7%, 5/12) of these had clinical symptoms during HBT indicating lactose intolerance (LI). Decreased blood glucose concentration increments (⩽20 mg dL −1 (⩽1.1 mmol L −1 )) were found in 3/5 of these patients. CH4 concentrations ⩾10 ppm at any time during the test were observed in 5/32 (15.6%) patients and in 9/32 (28.1%) between 1 ppm and 9 ppm above baseline after lactose ingestion. In patients with positive HBT 10/12 (83.3%) showed elevated CH4 (>1 ppm) above baseline in breath gas, whereas in patients with negative HBT this figure was only 4/17 (23.5%). In addition to determining H2 in exhaled air, documentation of clinical symptoms, measurement of blood glucose and breath CH4 concentrations may be helpful in deciding whether in a given case an HBT correctly identifies patients with clinically relevant LM. … (more)
- Is Part Of:
- Journal of breath research. Volume 10:Number 1(2016:Mar.)
- Journal:
- Journal of breath research
- Issue:
- Volume 10:Number 1(2016:Mar.)
- Issue Display:
- Volume 10, Issue 1 (2016)
- Year:
- 2016
- Volume:
- 10
- Issue:
- 1
- Issue Sort Value:
- 2016-0010-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-03-02
- Subjects:
- hydrogen breath test -- child -- lactose -- malabsorption -- methane
Volatile organic compounds -- Analysis -- Periodicals
Clinical chemistry -- Periodicals
Bad breath -- Periodicals
Bad breath -- Treatment -- Periodicals
Bad breath -- Diagnosis -- Periodicals
616.0756 - Journal URLs:
- http://iopscience.iop.org/1752-7163/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1752-7155/10/1/016015 ↗
- Languages:
- English
- ISSNs:
- 1752-7155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11104.xml