Carbon ions beam therapy monitoring with the INSIDE in-beam PET. (17th July 2018)
- Record Type:
- Journal Article
- Title:
- Carbon ions beam therapy monitoring with the INSIDE in-beam PET. (17th July 2018)
- Main Title:
- Carbon ions beam therapy monitoring with the INSIDE in-beam PET
- Authors:
- Pennazio, Francesco
Battistoni, Giuseppe
Bisogni, Maria Giuseppina
Camarlinghi, Niccolò
Ferrari, Alfredo
Ferrero, Veronica
Fiorina, Elisa
Morrocchi, Matteo
Sala, Paola
Sportelli, Giancarlo
Wheadon, Richard
Cerello, Piergiorgio - Abstract:
- Abstract: In vivo range monitoring techniques are necessary in order to fully take advantage of the high dose gradients deliverable in hadrontherapy treatments. Positron emission tomography (PET) scanners can be used to monitor beam-induced activation in tissues and hence measure the range. The INSIDE (Innovative Solutions for In-beam DosimEtry in Hadrontherapy) in-beam PET scanner, installed at the Italian National Center of Oncological Hadrontherapy (CNAO, Pavia, Italy) synchrotron facility, has already been successfully tested in vivo during a proton therapy treatment. We discuss here the system performance evaluation with carbon ion beams, in view of future in vivo tests. The work is focused on the analysis of activity images obtained with therapeutic treatments delivered to polymethyl methacrylate (PMMA) phantoms, as well as on the test of an innovative and robust Monte Carlo simulation technique for the production of reliable prior activity maps. Images are reconstructed using different integration intervals, so as to monitor the activity evolution during and after the treatment. Three procedures to compare activity images are presented, namely Pearson correlation coefficient, Beam's eye view and overall view. Images of repeated irradiations of the same treatments are compared to assess the integration time necessary to provide reproducible images. The range agreement between simulated and experimental images is also evaluated, so as to validate the simulationAbstract: In vivo range monitoring techniques are necessary in order to fully take advantage of the high dose gradients deliverable in hadrontherapy treatments. Positron emission tomography (PET) scanners can be used to monitor beam-induced activation in tissues and hence measure the range. The INSIDE (Innovative Solutions for In-beam DosimEtry in Hadrontherapy) in-beam PET scanner, installed at the Italian National Center of Oncological Hadrontherapy (CNAO, Pavia, Italy) synchrotron facility, has already been successfully tested in vivo during a proton therapy treatment. We discuss here the system performance evaluation with carbon ion beams, in view of future in vivo tests. The work is focused on the analysis of activity images obtained with therapeutic treatments delivered to polymethyl methacrylate (PMMA) phantoms, as well as on the test of an innovative and robust Monte Carlo simulation technique for the production of reliable prior activity maps. Images are reconstructed using different integration intervals, so as to monitor the activity evolution during and after the treatment. Three procedures to compare activity images are presented, namely Pearson correlation coefficient, Beam's eye view and overall view. Images of repeated irradiations of the same treatments are compared to assess the integration time necessary to provide reproducible images. The range agreement between simulated and experimental images is also evaluated, so as to validate the simulation capability to provide sound prior information. The results indicate that at treatment end, or at most 20 s afterwards, the range measurement is reliable within 1–2 mm, when comparing both different experimental sessions and data with simulations. In conclusion, this work shows that the INSIDE in-beam PET scanner performance is promising towards its in vivo test with carbon ions. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 63:Number 14(2018:Jul.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 63:Number 14(2018:Jul.)
- Issue Display:
- Volume 63, Issue 14 (2018)
- Year:
- 2018
- Volume:
- 63
- Issue:
- 14
- Issue Sort Value:
- 2018-0063-0014-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-07-17
- Subjects:
- in-beam PET -- hadrontherapy -- Monte Carlo simulations -- range monitoring
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aacab8 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11099.xml