Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise. (September 2019)
- Record Type:
- Journal Article
- Title:
- Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise. (September 2019)
- Main Title:
- Validity and reliability of the WIMU® system to measure barbell velocity during the half-squat exercise
- Authors:
- García-Pinillos, Felipe
Latorre-Román, Pedro A
Valdivieso-Ruano, Fernando
Balsalobre-Fernández, Carlos
Párraga-Montilla, Juan A - Abstract:
- This study aimed at determining the reliability and concurrent validity of the WIMU ® system when measuring barbell velocity during the half-squat exercise by comparing data with the gold standard. A total of 19 male competitive powerlifters performed an incremental loading test using the half-squat exercise. The mean velocity, mean propulsive velocity and maximum velocity of all repetitions were recorded through both WIMU and T-Force systems. As a measure of reliability, coefficient of variations ranged from 6%–17% and standard error of means ranged from 0.02–0.11 m/s, showing very close reliability of data from both devices. Validity, in terms of coefficient of correlations and pairwise comparisons, was also tested. Except for some relative loads, the Pearson correlation analysis revealed significant correlations between both devices for mean velocity, mean propulsive velocity and maximum velocity (r > 0.6, p < 0.05). The mean velocity, mean propulsive velocity and maximum velocity were underestimated for the WIMU system compared to T-Force data at some points of the load–velocity relationship. The linear regression models performed revealed a strong load–velocity relationship in the half-squat exercise for each individual using mean velocity, mean propulsive velocity and maximum velocity, regardless of the instrument used (R 2 > 0.77 in all cases). Bland–Altman plots revealed low systematic bias (≤0.06 m s −1 ) and random error (≤0.07 m s −1 ) for the mean velocity andThis study aimed at determining the reliability and concurrent validity of the WIMU ® system when measuring barbell velocity during the half-squat exercise by comparing data with the gold standard. A total of 19 male competitive powerlifters performed an incremental loading test using the half-squat exercise. The mean velocity, mean propulsive velocity and maximum velocity of all repetitions were recorded through both WIMU and T-Force systems. As a measure of reliability, coefficient of variations ranged from 6%–17% and standard error of means ranged from 0.02–0.11 m/s, showing very close reliability of data from both devices. Validity, in terms of coefficient of correlations and pairwise comparisons, was also tested. Except for some relative loads, the Pearson correlation analysis revealed significant correlations between both devices for mean velocity, mean propulsive velocity and maximum velocity (r > 0.6, p < 0.05). The mean velocity, mean propulsive velocity and maximum velocity were underestimated for the WIMU system compared to T-Force data at some points of the load–velocity relationship. The linear regression models performed revealed a strong load–velocity relationship in the half-squat exercise for each individual using mean velocity, mean propulsive velocity and maximum velocity, regardless of the instrument used (R 2 > 0.77 in all cases). Bland–Altman plots revealed low systematic bias (≤0.06 m s −1 ) and random error (≤0.07 m s −1 ) for the mean velocity and mean propulsive velocity obtained from the WIMU system as compared to the T-Force, while the maximum velocity resulted in an underestimation by the WIMU system (–0.16 m s −1 ) as compared to the linear position transducer system. The results indicate that the WIMU system is a reliable tool for tracking barbell velocity in the half squat, but these data also reveal some limitations regarding its concurrent validity as compared to the gold standard, with velocity measures slightly underestimated in the tested conditions. … (more)
- Is Part Of:
- Proceedings of the Institution of Mechanical Engineers. Volume 233:Number 3(2019:Sep.)
- Journal:
- Proceedings of the Institution of Mechanical Engineers
- Issue:
- Volume 233:Number 3(2019:Sep.)
- Issue Display:
- Volume 233, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 233
- Issue:
- 3
- Issue Sort Value:
- 2019-0233-0003-0000
- Page Start:
- 408
- Page End:
- 415
- Publication Date:
- 2019-09
- Subjects:
- velocity-based training -- accelerometer -- inertial sensor -- resistance training
Sports sciences -- Periodicals
Sporting goods -- Design and construction -- Periodicals
Sports -- Technological innovations -- Periodicals
Biomechanics -- Periodicals
613.71 - Journal URLs:
- http://journals.pepublishing.com/content/120792 ↗
http://pip.sagepub.com ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1754337119831890 ↗
- Languages:
- English
- ISSNs:
- 1754-3371
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11118.xml