Double side read-out technique for mitigation of radiation damage effects in PbWO4 crystals. (18th April 2016)
- Record Type:
- Journal Article
- Title:
- Double side read-out technique for mitigation of radiation damage effects in PbWO4 crystals. (18th April 2016)
- Main Title:
- Double side read-out technique for mitigation of radiation damage effects in PbWO4 crystals
- Authors:
- Lucchini, M.T.
Auffray, E.
Benaglia, A.
Cavallari, F.
Cockerill, D.
Dolgopolov, A.
Faure, J.L.
Golubev, N.
Hobson, P.R.
Jain, S.
Korjik, M.
Mechinski, V.
Singovski, A.
de Fatis, T. Tabarelli
Tarasov, I.
Zahid, S. - Abstract:
- Abstract: Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m −1, have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct for event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. The double side read-out technique presented in this study provides a valuable way to improve theAbstract: Test beam results of a calorimetric module based on 3×3×22 cm 3 PbWO 4 crystals, identical to those used in the CMS ECAL Endcaps, read out by a pair of photodetectors coupled to the two opposite sides (front and rear) of each crystal are presented. Nine crystals with different level of induced absorption, from 0 to 20 m −1, have been tested using electrons in the 50–200 GeV energy range. Photomultiplier tubes have been chosen as photodetectors to allow for a precise measurement of highly damaged crystals. The information provided by this double side read-out configuration allows to correct for event-by-event fluctuations of the longitudinal development of electromagnetic showers. By strongly mitigating the effect of non-uniform light collection efficiency induced by radiation damage, the double side read-out technique significantly improves the energy resolution with respect to a single side read-out configuration. The non-linearity of the response arising in damaged crystals is also corrected by a double side read-out configuration and the response linearity of irradiated crystals is restored. In high radiation environments at future colliders, as it will be the case for detectors operating during the High Luminosity phase of the Large Hadron Collider, defects can be created inside the scintillator volume leading to a non-uniform response of the calorimetric cell. The double side read-out technique presented in this study provides a valuable way to improve the performance of calorimeters based on scintillators whose active volumes are characterized by high aspect ratio cells similar to those used in this study. … (more)
- Is Part Of:
- Journal of instrumentation. Volume 11:Number 4(2016:Apr.)
- Journal:
- Journal of instrumentation
- Issue:
- Volume 11:Number 4(2016:Apr.)
- Issue Display:
- Volume 11, Issue 4 (2016)
- Year:
- 2016
- Volume:
- 11
- Issue:
- 4
- Issue Sort Value:
- 2016-0011-0004-0000
- Page Start:
- P04021
- Page End:
- P04021
- Publication Date:
- 2016-04-18
- Subjects:
- Calorimeter methods -- Calorimeters -- Radiation damage to detector materials (solid state) -- Radiation-hard detectors
Scientific apparatus and instruments -- Periodicals
502.84 - Journal URLs:
- http://iopscience.iop.org/1748-0221 ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1748-0221/11/04/P04021 ↗
- Languages:
- English
- ISSNs:
- 1748-0221
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11086.xml