A new measurement method of actual focal spot position of an x-ray tube using a high-precision carbon-interspaced grid. (19th April 2018)
- Record Type:
- Journal Article
- Title:
- A new measurement method of actual focal spot position of an x-ray tube using a high-precision carbon-interspaced grid. (19th April 2018)
- Main Title:
- A new measurement method of actual focal spot position of an x-ray tube using a high-precision carbon-interspaced grid
- Authors:
- Lee, H W
Lim, H W
Jeon, D H
Park, C K
Cho, H S
Seo, C W
Lee, D Y
Kim, K S
Kim, G A
Park, S Y
Kang, S Y
Park, J E
Kim, W S
Woo, T H
Oh, J E - Abstract:
- Abstract: This study investigated the effectiveness of a new method for measuring the actual focal spot position of a diagnostic x-ray tube using a high-precision antiscatter grid and a digital x-ray detector in which grid magnification, which is directly related to the focal spot position, was determined from the Fourier spectrum of the acquired x-ray grid's image. A systematic experiment was performed to demonstrate the viability of the proposed measurement method. The hardware system used in the experiment consisted of an x-ray tube run at 50 kVp and 1 mA, a flat-panel detector with a pixel size of 49.5 µ m, and a high-precision carbon-interspaced grid with a strip density of 200 lines/inch. The results indicated that the focal spot of the x-ray tube (Jupiter 5000, Oxford Instruments) used in the experiment was located approximately 31.10 mm inside from the exit flange, well agreed with the nominal value of 31.05 mm, which demonstrates the viability of the proposed measurement method. Thus, the proposed method can be utilized for system's performance optimization in many x-ray imaging applications.
- Is Part Of:
- Measurement science & technology. Volume 29:Number 6(2018:Jun.)
- Journal:
- Measurement science & technology
- Issue:
- Volume 29:Number 6(2018:Jun.)
- Issue Display:
- Volume 29, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 29
- Issue:
- 6
- Issue Sort Value:
- 2018-0029-0006-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-04-19
- Subjects:
- focal spot position -- x-ray tube -- antiscatter grid -- system optimization
Physical measurements -- Periodicals
Scientific apparatus and instruments -- Periodicals
Equipment and Supplies -- Periodicals
Science -- instrumentation -- Periodicals
Technology -- instrumentation -- Periodicals
Mesures physiques -- Périodiques
Physical measurements
Scientific apparatus and instruments
Periodicals
502.87 - Journal URLs:
- http://iopscience.iop.org/0957-0233/ ↗
http://www.iop.org/Journals/mt ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6501/aab473 ↗
- Languages:
- English
- ISSNs:
- 0957-0233
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11076.xml