A depth-encoding PET detector that uses light sharing and single-ended readout with silicon photomultipliers. (13th February 2018)
- Record Type:
- Journal Article
- Title:
- A depth-encoding PET detector that uses light sharing and single-ended readout with silicon photomultipliers. (13th February 2018)
- Main Title:
- A depth-encoding PET detector that uses light sharing and single-ended readout with silicon photomultipliers
- Authors:
- Kuang, Zhonghua
Yang, Qian
Wang, Xiaohui
Fu, Xin
Ren, Ning
Sang, Ziru
Wu, San
Zheng, Yunfei
Zhang, Xianming
Hu, Zhanli
Du, Junwei
Liang, Dong
Liu, Xin
Zheng, Hairong
Yang, Yongfeng - Abstract:
- Abstract: Detectors with depth-encoding capability and good timing resolution are required to develop high-performance whole-body or total-body PET scanners. In this work, depth-encoding PET detectors that use light sharing between two discrete crystals and single-ended readout with silicon photomultipliers (SiPMs) were manufactured and evaluated. The detectors consisted of two unpolished 3 × 3 × 20 mm 3 LYSO crystals with different coupling materials between them and were read out by Hamamatsu 3 × 3 mm 2 SiPMs with one-to-one coupling. The ratio of the energy of one SiPM to the total energy of two SiPMs was used to measure the depth of interaction (DOI). Detectors with different coupling materials in-between the crystals were measured in the singles mode in an effort to obtain detectors that can provide good DOI resolution. The DOI resolution and energy resolution of three types of detector were measured and the timing resolution was measured for the detector with the best DOI and energy resolution. The optimum detector, with 5 mm optical glue, a 9 mm triangular ESR and a 6 mm rectangular ESR in-between the unpolished crystals, provides a DOI resolution of 2.65 mm, an energy resolution of 10.0% and a timing resolution of 427 ps for events of E > 400 keV. The detectors simultaneously provide good DOI and timing resolution, and show great promise for the development of high-performance whole-body and total-body PET scanners.
- Is Part Of:
- Physics in medicine & biology. Volume 63:Number 4(2018:Feb.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 63:Number 4(2018:Feb.)
- Issue Display:
- Volume 63, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 63
- Issue:
- 4
- Issue Sort Value:
- 2018-0063-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02-13
- Subjects:
- whole- body PET -- SiPM -- depth-encoding -- light sharing -- single-ended readout
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aaa94e ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11081.xml