New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy. (26th February 2018)
- Record Type:
- Journal Article
- Title:
- New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy. (26th February 2018)
- Main Title:
- New photoplethysmogram indicators for improving cuffless and continuous blood pressure estimation accuracy
- Authors:
- Lin, Wan-Hua
Wang, Hui
Samuel, Oluwarotimi Williams
Liu, Gengxing
Huang, Zhen
Li, Guanglin - Abstract:
- Abstract: Objective : The accuracy of cuffless and continuous blood pressure (BP) estimation has been improved, but it is still unsatisfactory for clinical uses. This study was designed to further increase BP estimation accuracy. Approach : In this study, a number of new indicators were extracted from photoplethysmogram (PPG) recordings and a linear regression method was used to construct BP estimation models based on the PPG indicators and pulse transit time (PTT). The performance of the BP estimation models was evaluated by the PPG recordings from 22 subjects when they performed mental arithmetic stress and Valsalva's manoeuvre tasks that could induce BP fluctuations. Main results : Our results showed that the best PPG-based BP estimation model could achieve a decrease of 0.31 ± 0.08 mmHg in systolic BP (SBP) and 0.33 ± 0.01 mmHg in diastolic BP (DBP) on estimation errors of grand absolute mean (GAM) and standard deviation (GSD) in comparison to the previously reported PPG-based methods. The best estimation model based on the combination of PPG and PPT could achieve a decrease (GAM & GSD) of 0.81 ± 0.95 mmHg in SBP and 0.75 ± 0.54 mmHg in DBP in comparison to the PPT-based methods. Significance : The findings suggest that the newly proposed PPG indicators would be promising for improving the accuracy of continuous and cuffless BP estimation.
- Is Part Of:
- Physiological measurement. Volume 39:Number 2(2018:Feb.)
- Journal:
- Physiological measurement
- Issue:
- Volume 39:Number 2(2018:Feb.)
- Issue Display:
- Volume 39, Issue 2 (2018)
- Year:
- 2018
- Volume:
- 39
- Issue:
- 2
- Issue Sort Value:
- 2018-0039-0002-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-02-26
- Subjects:
- blood pressure -- continuous and cuffless estimation -- photoplethysmogram indicators -- pulse transit time
Physiology -- Measurement -- Periodicals
Patient monitoring -- Periodicals
612 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0967-3334 ↗ - DOI:
- 10.1088/1361-6579/aaa454 ↗
- Languages:
- English
- ISSNs:
- 0967-3334
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11079.xml