Study of the reliability of quantification methods of dynamic contrast-enhanced ultrasonography: numerical modeling of blood flow in tumor microvascularization. (23rd August 2018)
- Record Type:
- Journal Article
- Title:
- Study of the reliability of quantification methods of dynamic contrast-enhanced ultrasonography: numerical modeling of blood flow in tumor microvascularization. (23rd August 2018)
- Main Title:
- Study of the reliability of quantification methods of dynamic contrast-enhanced ultrasonography: numerical modeling of blood flow in tumor microvascularization
- Authors:
- Boyer, Laure
Leguerney, Ingrid
Randall Thomas, S
Grand-Perret, Virginie
Lassau, Nathalie
Pitre-Champagnat, Stephanie - Abstract:
- Abstract: Dynamic contrast-enhanced ultrasonography is a recent functional dynamic imaging technique that allows evaluation of the efficacy of anti-angiogenic treatments by quantifying changes in specific parameters of the tumor vasculature. Preclinical and clinical experimental studies now reveal the existence of sources of variability in the quantitative methods. In order to study the reliability of quantification methods (both semi-quantitative and quantitative), we have developed the first numerical model of blood flow and contrast agents in vascular networks with computational fluid dynamics Fluent software version 15.0 (ANSYS, France). We studied four vascular networks (1.84 × 10 −3, 2.28 × 10 −3, 2.4 × 10 −3 and 2.54 × 10 −3 ml) and four blood velocities (0.01, 0.02, 0.03 and 0.05 m s −1 ). For variations in tumor vascular volume the quantitative method is more sensitive, with variations of parameter perfusion of 25.7%, in contrast to variations of the semi-quantitative parameters between 14.9 and 19.5%. For changes in blood velocity the semi-quantitative method is more sensitive, with variation of the area under the enhancement curve (64%), the maximum of the enhancement curve (60%), and the slope of the enhancement curve (73%). The transit time parameters from the two quantitative methods were weakly sensitive to both blood volume and blood flow variations. This study is hopeful and may be extended to the treatment of more complex vascular networks, toAbstract: Dynamic contrast-enhanced ultrasonography is a recent functional dynamic imaging technique that allows evaluation of the efficacy of anti-angiogenic treatments by quantifying changes in specific parameters of the tumor vasculature. Preclinical and clinical experimental studies now reveal the existence of sources of variability in the quantitative methods. In order to study the reliability of quantification methods (both semi-quantitative and quantitative), we have developed the first numerical model of blood flow and contrast agents in vascular networks with computational fluid dynamics Fluent software version 15.0 (ANSYS, France). We studied four vascular networks (1.84 × 10 −3, 2.28 × 10 −3, 2.4 × 10 −3 and 2.54 × 10 −3 ml) and four blood velocities (0.01, 0.02, 0.03 and 0.05 m s −1 ). For variations in tumor vascular volume the quantitative method is more sensitive, with variations of parameter perfusion of 25.7%, in contrast to variations of the semi-quantitative parameters between 14.9 and 19.5%. For changes in blood velocity the semi-quantitative method is more sensitive, with variation of the area under the enhancement curve (64%), the maximum of the enhancement curve (60%), and the slope of the enhancement curve (73%). The transit time parameters from the two quantitative methods were weakly sensitive to both blood volume and blood flow variations. This study is hopeful and may be extended to the treatment of more complex vascular networks, to approach clinical conditions, and to the evaluation of quantification methods in contrast imaging. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 63:Number 17(2018:Sep.)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 63:Number 17(2018:Sep.)
- Issue Display:
- Volume 63, Issue 17 (2018)
- Year:
- 2018
- Volume:
- 63
- Issue:
- 17
- Issue Sort Value:
- 2018-0063-0017-0000
- Page Start:
- Page End:
- Publication Date:
- 2018-08-23
- Subjects:
- numerical modeling -- dynamic contrast-enhanced ultrasonography -- computational fluid dynamics -- tumor vasculature -- microcirculation
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/aad6ae ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11065.xml