A novel method for comparing radiation dose and image quality, between and within different x-ray units in a series of hospitals. (18th October 2018)
- Record Type:
- Journal Article
- Title:
- A novel method for comparing radiation dose and image quality, between and within different x-ray units in a series of hospitals. (18th October 2018)
- Main Title:
- A novel method for comparing radiation dose and image quality, between and within different x-ray units in a series of hospitals
- Authors:
- Al-Murshedi, Sadeq
Hogg, Peter
Lanca, Luis
England, Andrew - Abstract:
- Abstract: Objectives: To develop a novel method for comparing radiation dose and image quality (IQ) to evaluate adult chest x-ray (CXR) imaging among several hospitals. Methods: CDRAD 2.0 phantom was used to acquire images in eight hospitals (17 digital x-ray units) using local adult CXR protocols. IQ was represented by image quality figure inverse (IQFinv ), measured using CDRAD analyser software. Signal to noise ratio, contrast to noise ratio and conspicuity index were calculated as additional measures of IQ. Incident air kerma (IAK) was measured using a solid-state dosimeter for each acquisition. Figure of merit (FOM) was calculated to provide a single estimation of IQ and radiation dose. Results: IQ, radiation dose and FOM varied considerably between hospitals and x-ray units. For IQFinv, the mean (range) between and within the hospitals were 1.42 (0.83–2.18) and 1.87 (1.52–2.18), respectively. For IAK, the mean (range) between and within the hospitals were 93.56 (17.26–239.15) μ Gy and 180.85 (122.58–239.15) μ Gy, respectively. For FOM, the mean (range) between and within hospitals were 0.05 (0.01–0.14) and 0.03 (0.02–0.05), respectively. Conclusions: The suggested method for comparing IQ and dose using FOM concept along with the new proposed FOM, is a valid, reliable and effective approach for monitoring and comparing IQ and dose between and within hospitals. It is also can be beneficial for the optimisation of x-ray units in clinical practice. Further optimisation forAbstract: Objectives: To develop a novel method for comparing radiation dose and image quality (IQ) to evaluate adult chest x-ray (CXR) imaging among several hospitals. Methods: CDRAD 2.0 phantom was used to acquire images in eight hospitals (17 digital x-ray units) using local adult CXR protocols. IQ was represented by image quality figure inverse (IQFinv ), measured using CDRAD analyser software. Signal to noise ratio, contrast to noise ratio and conspicuity index were calculated as additional measures of IQ. Incident air kerma (IAK) was measured using a solid-state dosimeter for each acquisition. Figure of merit (FOM) was calculated to provide a single estimation of IQ and radiation dose. Results: IQ, radiation dose and FOM varied considerably between hospitals and x-ray units. For IQFinv, the mean (range) between and within the hospitals were 1.42 (0.83–2.18) and 1.87 (1.52–2.18), respectively. For IAK, the mean (range) between and within the hospitals were 93.56 (17.26–239.15) μ Gy and 180.85 (122.58–239.15) μ Gy, respectively. For FOM, the mean (range) between and within hospitals were 0.05 (0.01–0.14) and 0.03 (0.02–0.05), respectively. Conclusions: The suggested method for comparing IQ and dose using FOM concept along with the new proposed FOM, is a valid, reliable and effective approach for monitoring and comparing IQ and dose between and within hospitals. It is also can be beneficial for the optimisation of x-ray units in clinical practice. Further optimisation for the hospitals/x-ray units with low FOM are required to minimise radiation dose without degrading IQ. … (more)
- Is Part Of:
- Journal of radiological protection. Volume 38:Number 4(2018:Dec.)
- Journal:
- Journal of radiological protection
- Issue:
- Volume 38:Number 4(2018:Dec.)
- Issue Display:
- Volume 38, Issue 4 (2018)
- Year:
- 2018
- Volume:
- 38
- Issue:
- 4
- Issue Sort Value:
- 2018-0038-0004-0000
- Page Start:
- 1344
- Page End:
- 1358
- Publication Date:
- 2018-10-18
- Subjects:
- image quality -- radiation dose -- dose optimisation -- adult chest radiography -- CDRAD 2.0 phantom
Radiation -- Safety measures -- Periodicals
Health Physics -- Periodicals
Radiation Monitoring -- Periodicals
Radiation Protection -- Periodicals
Rayonnement -- Sécurité -- Mesures -- Périodiques
Electronic journals
Fulltext
Internet Resource
Periodical
363.179905 - Journal URLs:
- http://www.iop.org/EJ/journal/JRP ↗
http://iopscience.iop.org/0952-4746/ ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1361-6498/aae3fa ↗
- Languages:
- English
- ISSNs:
- 0952-4746
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11064.xml