XAP-Lab: A software tool for designing flexible X-ray acquisition protocols. (August 2019)
- Record Type:
- Journal Article
- Title:
- XAP-Lab: A software tool for designing flexible X-ray acquisition protocols. (August 2019)
- Main Title:
- XAP-Lab: A software tool for designing flexible X-ray acquisition protocols
- Authors:
- Martínez, A.
García-Santos, A.
Ballesteros, N.
Desco, M.
Abella, M. - Abstract:
- Highlights: Interactive software tool to support the flexible design of X-ray acquisition protocols. Valid to evaluate new tomography applications with non-standard geometrical configurations. It provides additional information such as scanned field of view and total radiation dose. Simulation in near real time thanks to the GPU implementation of the projection kernel. The modular design enables an easy integration of new modules and features. Abstract: Background and objective: The availability of digital X-ray detectors, together with the development of new robotized hardware and reconstruction algorithms, opens the opportunity to provide 3D capabilities with conventional radiology systems. This would be based on the acquisition of a limited number of projections with non-standard geometrical configurations. The versatility of these techniques is enormous, enabling the introduction of tomography in situations where a CT system is hardly available, such as during surgery or in an ICU, or in which a reduction of radiation dose is key, as in pediatrics. Computer simulations are a valuable tool to explore these possibilities before their actual implementation on real systems. Existing software tools generally simulate only standard acquisition protocols, such as cone-beam with circular trajectory, thus not allowing the users to evaluate more sophisticated projection geometries. The goal of this work is to design a simulation tool that enables the design of acquisitionHighlights: Interactive software tool to support the flexible design of X-ray acquisition protocols. Valid to evaluate new tomography applications with non-standard geometrical configurations. It provides additional information such as scanned field of view and total radiation dose. Simulation in near real time thanks to the GPU implementation of the projection kernel. The modular design enables an easy integration of new modules and features. Abstract: Background and objective: The availability of digital X-ray detectors, together with the development of new robotized hardware and reconstruction algorithms, opens the opportunity to provide 3D capabilities with conventional radiology systems. This would be based on the acquisition of a limited number of projections with non-standard geometrical configurations. The versatility of these techniques is enormous, enabling the introduction of tomography in situations where a CT system is hardly available, such as during surgery or in an ICU, or in which a reduction of radiation dose is key, as in pediatrics. Computer simulations are a valuable tool to explore these possibilities before their actual implementation on real systems. Existing software tools generally simulate only standard acquisition protocols, such as cone-beam with circular trajectory, thus not allowing the users to evaluate more sophisticated projection geometries. The goal of this work is to design a simulation tool that enables the design of acquisition protocols with flexible projection geometries. Methods: We present XAP-Lab, a software tool for the design of X-ray acquisition protocols with flexible trajectories. For a given projection geometry, defined through a graphical user interface, it allows the user to simulate projections using GPU-accelerated kernels, the visualization of the scanned field of view and the estimation of the total radiation dose. The complete acquisition protocol can then be exported with the appropriate format for its use on real systems. We tested the software by optimizing a tomosynthesis protocol and validating the results with real acquisitions using a SEDECAL NOVA FA radiography system and phantoms for quantitative and qualitative evaluation. Results: Quantitative evaluation using a phantom showed a mean error under 4 mm for each position, below the ±5 mm tolerance of the system specified by the manufacturer. Visual evaluation on a thorax acquisition also showed a good geometrical agreement between simulated and real projections. Conclusions: Results showed an excellent matching with simulations, supporting the usefulness of XAP-Lab for the design of new acquisition protocols with non-standard geometries. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 177(2019)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 177(2019)
- Issue Display:
- Volume 177, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 177
- Issue:
- 2019
- Issue Sort Value:
- 2019-0177-2019-0000
- Page Start:
- 243
- Page End:
- 252
- Publication Date:
- 2019-08
- Subjects:
- Simulation -- X-ray -- Acquisition protocol -- Radiology system -- Tomography -- System geometry
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2019.05.013 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11049.xml