Static and dynamic abductor function are both associated with physical function 1 to 5 years after total hip arthroplasty. (July 2019)
- Record Type:
- Journal Article
- Title:
- Static and dynamic abductor function are both associated with physical function 1 to 5 years after total hip arthroplasty. (July 2019)
- Main Title:
- Static and dynamic abductor function are both associated with physical function 1 to 5 years after total hip arthroplasty
- Authors:
- Cinnamon, Christopher C.
Longworth, Jessica A.
Brunner, J. Heather
Chau, Vivian K.
Ryan, Colleen A.
Dapiton, Kris R.
Chmell, Samuel J.
Foucher, Kharma C. - Abstract:
- Abstract: Background: A subset of total hip arthroplasty patients experience functional impairments past the first postoperative year. Poor hip abductor function is common before and in the early postoperative period. It is not known if abductor impairment is associated with long-term functional impairment. This study evaluated the relationships between static and dynamic abductor function and performance-based and self-reported function >1 year post-total hip arthroplasty. Methods: Eighteen adults 1–5 years post-total hip arthroplasty participated. Static and dynamic abductor function were assessed through dynamometry and gait analysis, respectively. Subjects completed four physical performance tests and two self-report instruments. Findings: Higher peak isometric abductor strength was associated with better performance-based function ( P ≤ 0.001–0.030) and with self-reported function ( P ≤ 0.001–0.012). Higher peak external adduction moment was associated with better results on 3 of 4 performance tests ( P = 0.007–0.026). Together, static and dynamic abductor function predicted 35–77% of the variation in physical function. Abductor strength best predicted walking test results and self-reported function, while dynamic abductor function best predicted tests involving sit-to-stand Interpretation: Static and dynamic abductor function were associated with physical function 1–5 years after total hip arthroplasty. These results support further investigation of interventionsAbstract: Background: A subset of total hip arthroplasty patients experience functional impairments past the first postoperative year. Poor hip abductor function is common before and in the early postoperative period. It is not known if abductor impairment is associated with long-term functional impairment. This study evaluated the relationships between static and dynamic abductor function and performance-based and self-reported function >1 year post-total hip arthroplasty. Methods: Eighteen adults 1–5 years post-total hip arthroplasty participated. Static and dynamic abductor function were assessed through dynamometry and gait analysis, respectively. Subjects completed four physical performance tests and two self-report instruments. Findings: Higher peak isometric abductor strength was associated with better performance-based function ( P ≤ 0.001–0.030) and with self-reported function ( P ≤ 0.001–0.012). Higher peak external adduction moment was associated with better results on 3 of 4 performance tests ( P = 0.007–0.026). Together, static and dynamic abductor function predicted 35–77% of the variation in physical function. Abductor strength best predicted walking test results and self-reported function, while dynamic abductor function best predicted tests involving sit-to-stand Interpretation: Static and dynamic abductor function were associated with physical function 1–5 years after total hip arthroplasty. These results support further investigation of interventions targeting abductor function for persons experiencing persistent impairments. Highlights: Hip abductor strength is associated with performance tests after total hip arthroplasty. Hip abductor strength is associated with self-reported function after total hip arthroplasty. Peak external adduction moments are associated with most performance tests. Peak external adduction moments are not associated with self-reported function. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 67(2019)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 67(2019)
- Issue Display:
- Volume 67, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 67
- Issue:
- 2019
- Issue Sort Value:
- 2019-0067-2019-0000
- Page Start:
- 127
- Page End:
- 133
- Publication Date:
- 2019-07
- Subjects:
- Total hip arthroplasty -- Total hip replacement -- Hip abductors -- Functional impairment -- Persistent impairment -- Rehabilitation
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2019.05.009 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11024.xml