Biomechanical and geometric characterization of peroneus longus allografts with respect to age. (July 2019)
- Record Type:
- Journal Article
- Title:
- Biomechanical and geometric characterization of peroneus longus allografts with respect to age. (July 2019)
- Main Title:
- Biomechanical and geometric characterization of peroneus longus allografts with respect to age
- Authors:
- Wong, Andrew K.
Calvo M., Rafael
Schaffler, Benjamin C.
Nixon, Ryan A.
Carrero, Leanza C.
Neufeld, Eric V.
Grande, Daniel A.
Calvo R., Rafael - Abstract:
- Abstract: Background: Anterior cruciate ligament injuries are among the most common injuries in high impact sports, and reconstruction is the standard surgical procedure for these ruptures. Reconstructions are often performed using allografts rather than autografts on a case-by-case basis. Controversy exists as to whether or not age of donor tissue plays a factor in the mechanical properties of allografts. Methods: 38 peroneus longus (PL) tendons were prepared using the two-strand graft technique and then subjected to a cyclic loading test regimen of 1000 cycles to determine material properties. Specimens were grouped based on age to ascertain whether donor age affects the material properties of PL tendons. Findings: Secant modulus of the first cycle was determined to be 150.43 (SD 40.24) MPa. The average magnitude of the dynamic modulus was determined to be 82.81 (SD 24.65) MPa. Specimens were grouped into three distinct groups for analysis (x < 40 yo, 40 yo ≤ x < 60 yo, 60 yo < x). Interpretation: The need for using intrinsic material properties is highlighted. There is no significant difference in any intrinsic material property with respect to age or the fatigue of the tendon as the cycle count increases. Conversely, the measured stiffness of a tendon decreased as function of age with a large effect size. Based on analysis of graft geometries, it was determined that PL tendons become significantly more slender with increased age which result in the observed decrease inAbstract: Background: Anterior cruciate ligament injuries are among the most common injuries in high impact sports, and reconstruction is the standard surgical procedure for these ruptures. Reconstructions are often performed using allografts rather than autografts on a case-by-case basis. Controversy exists as to whether or not age of donor tissue plays a factor in the mechanical properties of allografts. Methods: 38 peroneus longus (PL) tendons were prepared using the two-strand graft technique and then subjected to a cyclic loading test regimen of 1000 cycles to determine material properties. Specimens were grouped based on age to ascertain whether donor age affects the material properties of PL tendons. Findings: Secant modulus of the first cycle was determined to be 150.43 (SD 40.24) MPa. The average magnitude of the dynamic modulus was determined to be 82.81 (SD 24.65) MPa. Specimens were grouped into three distinct groups for analysis (x < 40 yo, 40 yo ≤ x < 60 yo, 60 yo < x). Interpretation: The need for using intrinsic material properties is highlighted. There is no significant difference in any intrinsic material property with respect to age or the fatigue of the tendon as the cycle count increases. Conversely, the measured stiffness of a tendon decreased as function of age with a large effect size. Based on analysis of graft geometries, it was determined that PL tendons become significantly more slender with increased age which result in the observed decrease in stiffness. Highlights: Material properties of peroneus longus allografts do not change with donor age. Using intrinsic material properties allows comparison between research groups. Stiffness of peroneus longus allografts decreases with donor age. Allografts become more slender with donor age, causing observed change in stiffness. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 67(2019)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 67(2019)
- Issue Display:
- Volume 67, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 67
- Issue:
- 2019
- Issue Sort Value:
- 2019-0067-2019-0000
- Page Start:
- 90
- Page End:
- 95
- Publication Date:
- 2019-07
- Subjects:
- Peroneus longus tendon -- ACL reconstruction -- Biomechanics
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2019.04.017 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11024.xml