Influence of Multimorbidity on Burden and Appropriateness of Implantable Cardioverter‐Defibrillator Therapies. Issue 7 (20th March 2019)
- Record Type:
- Journal Article
- Title:
- Influence of Multimorbidity on Burden and Appropriateness of Implantable Cardioverter‐Defibrillator Therapies. Issue 7 (20th March 2019)
- Main Title:
- Influence of Multimorbidity on Burden and Appropriateness of Implantable Cardioverter‐Defibrillator Therapies
- Authors:
- Hajduk, Alexandra M.
Gurwitz, Jerry H.
Tabada, Grace
Masoudi, Frederick A.
Magid, David J.
Greenlee, Robert T.
Sung, Sue Hee
Cassidy‐Bushrow, Andrea E.
Liu, Taylor I.
Reynolds, Kristi
Smith, David H.
Fiocchi, Frances
Goldberg, Robert
Gill, Thomas M.
Gupta, Nigel
Peterson, Pamela N.
Schuger, Claudio
Vidaillet, Humberto
Hammill, Stephen C.
Allore, Heather
Go, Alan S. - Abstract:
- Abstract : OBJECTIVE: To determine whether burden of multiple chronic conditions (MCCs) influences the risk of receiving inappropriate vs appropriate device therapies. DESIGN: Retrospective cohort study. SETTING: Seven US healthcare delivery systems. PARTICIPANTS: Adults with left ventricular systolic dysfunction receiving an implantable cardioverter‐defibrillator (ICD) for primary prevention. MEASUREMENTS: Data on 24 comorbid conditions were captured from electronic health records and categorized into quartiles of comorbidity burden (0‐3, 4‐5, 6‐7 and 8‐16). Incidence of ICD therapies (shock and antitachycardia pacing [ATP] therapies), including appropriateness, was collected for 3 years after implantation. Outcomes included time to first ICD therapy, total ICD therapy burden, and risk of inappropriate vs appropriate ICD therapy. RESULTS: Among 2235 patients (mean age = 69 ± 11 years, 75% men), the median number of comorbidities was 6 (interquartile range = 4‐8), with 98% having at least two comorbidities. During a mean 2.2 years of follow‐up, 18.3% of patients experienced at least one appropriate therapy and 9.9% experienced at least one inappropriate therapy. Higher comorbidity burden was associated with an increased risk of first inappropriate therapy (adjusted hazard ratio [HR] = 1.94 [95% confidence interval {CI} = 1.14‐3.31] for 4‐5 comorbidities; HR = 2.25 [95% CI = 1.25‐4.05] for 6‐7 comorbidities; and HR = 2.91 [95% CI = 1.54‐5.50] for 8‐16 comorbidities).Abstract : OBJECTIVE: To determine whether burden of multiple chronic conditions (MCCs) influences the risk of receiving inappropriate vs appropriate device therapies. DESIGN: Retrospective cohort study. SETTING: Seven US healthcare delivery systems. PARTICIPANTS: Adults with left ventricular systolic dysfunction receiving an implantable cardioverter‐defibrillator (ICD) for primary prevention. MEASUREMENTS: Data on 24 comorbid conditions were captured from electronic health records and categorized into quartiles of comorbidity burden (0‐3, 4‐5, 6‐7 and 8‐16). Incidence of ICD therapies (shock and antitachycardia pacing [ATP] therapies), including appropriateness, was collected for 3 years after implantation. Outcomes included time to first ICD therapy, total ICD therapy burden, and risk of inappropriate vs appropriate ICD therapy. RESULTS: Among 2235 patients (mean age = 69 ± 11 years, 75% men), the median number of comorbidities was 6 (interquartile range = 4‐8), with 98% having at least two comorbidities. During a mean 2.2 years of follow‐up, 18.3% of patients experienced at least one appropriate therapy and 9.9% experienced at least one inappropriate therapy. Higher comorbidity burden was associated with an increased risk of first inappropriate therapy (adjusted hazard ratio [HR] = 1.94 [95% confidence interval {CI} = 1.14‐3.31] for 4‐5 comorbidities; HR = 2.25 [95% CI = 1.25‐4.05] for 6‐7 comorbidities; and HR = 2.91 [95% CI = 1.54‐5.50] for 8‐16 comorbidities). Participants with 8‐16 comorbidities had a higher total burden of ICD therapy (adjusted relative risk [RR] = 2.12 [95% CI = 1.43‐3.16]), a higher burden of inappropriate therapy (RR = 3.39 [95% CI = 1.67‐6.86]), and a higher risk of receiving inappropriate vs appropriate therapy (RR = 1.74 [95% CI = 1.07‐2.82]). Comorbidity burden was not significantly associated with receipt of appropriate ICD therapies. Patterns were similar when separately examining shock or ATP therapies. CONCLUSIONS: In primary prevention ICD recipients, MCC burden was independently associated with an increased risk of inappropriate but not appropriate device therapies. Comorbidity burden should be considered when engaging patients in shared decision making about ICD implantation. … (more)
- Is Part Of:
- Journal of the American Geriatrics Society. Volume 67:Issue 7(2019)
- Journal:
- Journal of the American Geriatrics Society
- Issue:
- Volume 67:Issue 7(2019)
- Issue Display:
- Volume 67, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 67
- Issue:
- 7
- Issue Sort Value:
- 2019-0067-0007-0000
- Page Start:
- 1370
- Page End:
- 1378
- Publication Date:
- 2019-03-20
- Subjects:
- comorbidity -- multimorbidity -- chronic disease -- implantable cardioverter‐defibrillator -- patient‐centered outcomes
Geriatrics -- Periodicals
618.97 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0002-8614) ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-5415 ↗
http://www.blackwell-synergy.com/Journals/issuelist.asp?journal=jgs ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0002-8614;screen=info;ECOIP ↗ - DOI:
- 10.1111/jgs.15839 ↗
- Languages:
- English
- ISSNs:
- 0002-8614
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4686.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11039.xml