A free and simple computerized screening test for visual field defects. Issue 4 (26th May 2019)
- Record Type:
- Journal Article
- Title:
- A free and simple computerized screening test for visual field defects. Issue 4 (26th May 2019)
- Main Title:
- A free and simple computerized screening test for visual field defects
- Authors:
- Nordfang, Maria
Uhre, Valdemar
Robotham, Ro Julia
Kerry, Sheila J.
Frederiksen, Jette Lautrup
Starrfelt, Randi - Abstract:
- Abstract : About 30–40% of stroke patients suffer from visual field defects following injury. These can interfere with the standard neuropsychological assessment and complicate the interpretation of tests that use visual materials. However, information about the integrity of a patient's central visual field is often unavailable. We, therefore, designed a screening tool, the computerized visual field test (c‐VFT), specifically targeted at providing easily available, but rough, information about patients' central visual field. c‐VFT was tested in two samples of stroke patients. Eleven patients were tested on c‐VFT and on the Esterman test. Five patients were tested on c‐VFT and the Humphrey Visual Field Analyzer (HFA), central 10‐2. Criterion validity of the c‐VFT was investigated by calculating quadrantwise intraclass correlation for both comparisons. For the HFA comparison, we also calculated point‐to‐point intraclass correlation, sensitivity, and specificity. Analyses revealed moderately good correspondence between c‐VFT and the Esterman test, and between c‐VFT and HFA 10‐2, respectively. When looking specifically at test points within one degree of visual angle apart in the two tests, intraclass correlation increased. For these points, the sensitivity of c‐VFT was 0.89 and specificity was 0.97. While the c‐VFT is not designed to be diagnostic nor to replace the detailed visual field analysis, this study shows that it provides a reasonable screening of the central visualAbstract : About 30–40% of stroke patients suffer from visual field defects following injury. These can interfere with the standard neuropsychological assessment and complicate the interpretation of tests that use visual materials. However, information about the integrity of a patient's central visual field is often unavailable. We, therefore, designed a screening tool, the computerized visual field test (c‐VFT), specifically targeted at providing easily available, but rough, information about patients' central visual field. c‐VFT was tested in two samples of stroke patients. Eleven patients were tested on c‐VFT and on the Esterman test. Five patients were tested on c‐VFT and the Humphrey Visual Field Analyzer (HFA), central 10‐2. Criterion validity of the c‐VFT was investigated by calculating quadrantwise intraclass correlation for both comparisons. For the HFA comparison, we also calculated point‐to‐point intraclass correlation, sensitivity, and specificity. Analyses revealed moderately good correspondence between c‐VFT and the Esterman test, and between c‐VFT and HFA 10‐2, respectively. When looking specifically at test points within one degree of visual angle apart in the two tests, intraclass correlation increased. For these points, the sensitivity of c‐VFT was 0.89 and specificity was 0.97. While the c‐VFT is not designed to be diagnostic nor to replace the detailed visual field analysis, this study shows that it provides a reasonable screening of the central visual field. The test can easily be used and will be made freely available to neuropsychological clinicians and researchers. … (more)
- Is Part Of:
- Scandinavian journal of psychology. Volume 60:Issue 4(2019)
- Journal:
- Scandinavian journal of psychology
- Issue:
- Volume 60:Issue 4(2019)
- Issue Display:
- Volume 60, Issue 4 (2019)
- Year:
- 2019
- Volume:
- 60
- Issue:
- 4
- Issue Sort Value:
- 2019-0060-0004-0000
- Page Start:
- 289
- Page End:
- 294
- Publication Date:
- 2019-05-26
- Subjects:
- Anopia -- hemianopia -- neuropsychological assessment -- stroke -- visual field screening
Psychology -- Periodicals
150 - Journal URLs:
- http://www.blackwellpublishing.com/journal.asp?ref=0036-5564 ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1467-9450 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/sjop.12546 ↗
- Languages:
- English
- ISSNs:
- 0036-5564
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8087.520000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11018.xml