Clinical evaluation of a small implantable cardiac monitor with a long sensing vector. Issue 7 (5th June 2019)
- Record Type:
- Journal Article
- Title:
- Clinical evaluation of a small implantable cardiac monitor with a long sensing vector. Issue 7 (5th June 2019)
- Main Title:
- Clinical evaluation of a small implantable cardiac monitor with a long sensing vector
- Authors:
- Piorkowski, Christopher
Busch, Mathias
Nölker, Georg
Schmitt, Jörn
Roithinger, Franz Xaver
Young, Glenn
Táborský, Miloš
Herrmann, Gundula
Schmitz, Dietmar - Abstract:
- Abstract: Introduction: We conducted this study to show the safety and efficacy of a new implantable cardiac monitor (ICM), the BioMonitor 2 (Biotronik SE & Co. KG; Berlin, Germany), and to describe the arrhythmia detection performance. Methods: The BioMonitor 2 has an extended sensing vector and is implanted close to the heart. It can transmit up to six subcutaneous electrocardiogram strips by Home Monitoring each day. We enrolled 92 patients with a standard device indication for an ICM in a single‐arm, multicenter prospective trial. Patients were followed for 3 months, and 48‐h Holter recordings were used to evaluate the arrhythmia detection performance. Results: One patient withdrew consent and in one patient, the implantation failed. Two study device‐related serious adverse events were reported, satisfying the primary safety hypothesis. Implantations took 7.4 ± 4.4 min from skin cut to suture. At 1 week, the R‐wave amplitude was 0.75 ± 0.53 mV. In the 82 patients with completed Holter recordings, all patients with arrhythmias were correctly identified. False positive detections of arrhythmia were mostly irregular rhythms wrongly detected as atrial fibrillation (episode‐based positive predictive value 72.5%). Daily Home Monitoring transmission was 94.9% successful. Conclusion: Safety and efficacy of the new device has been demonstrated. The detected R‐wave amplitudes are large, leading to a low level of inappropriate detections due to over‐ or undersensing.
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 7(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 7(2019)
- Issue Display:
- Volume 42, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2019-0042-0007-0000
- Page Start:
- 1038
- Page End:
- 1046
- Publication Date:
- 2019-06-05
- Subjects:
- arrhythmia detection -- atrial fibrillation -- implantable cardiac monitor -- remote monitoring -- syncope
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13728 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11013.xml