Can Nonthermal Plasma Improve the Adhesion between Acrylic Resin for Ocular Prostheses and Silicone‐Based Relining Material?. Issue 6 (7th June 2019)
- Record Type:
- Journal Article
- Title:
- Can Nonthermal Plasma Improve the Adhesion between Acrylic Resin for Ocular Prostheses and Silicone‐Based Relining Material?. Issue 6 (7th June 2019)
- Main Title:
- Can Nonthermal Plasma Improve the Adhesion between Acrylic Resin for Ocular Prostheses and Silicone‐Based Relining Material?
- Authors:
- Nagay, Bruna Egumi
Goiato, Marcelo Coelho
da Silva, Emily Vivianne Freitas
de Medeiros, Rodrigo Antonio
Rangel, Elidiane Cipriano
da Cruz, Nilson Cristino
de Caxias, Fernanda Pereira
dos Santos, Daniela Micheline - Abstract:
- Abstract: Purpose: To investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat‐polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer. Materials and Methods: One‐hundred and sixty‐four acrylic resin specimens were fabricated and randomly distributed into four groups according to the type of surface treatment: Sofreliner Primer, NTP, Sofreliner Primer + NTP, and NTP + Sofreliner Primer. Two specimens interposed with relining material (Sofreliner) formed one test sample to perform the tensile bond strength tests, before (initial) and after storage (final) in saline solution (37°C, 90 days, n = 10). Surface characterization was performed by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The failure type was classified as cohesive, adhesive, or mixed. The data were analyzed statistically using the two‐way ANOVA and Tukey test, as well as the chi‐squared test ( α = 0.05), Bonferroni correction ( α = 0.005), and Spearman correlation coefficient ( α = 0.05). Results: The SEM and EDS analyses showed the presence of a thin, homogenous organic film in the groups treated with NTP. The NTP + Sofreliner Primer group presented the largest bond strength mean values in the initial period ( p < 0.05). Sofreliner Primer and NTP + Sofreliner Primer groups presented the first and second largest tensile bond strength mean values in the final period ( p <Abstract: Purpose: To investigate the influence of nonthermal plasma (NTP) treatment on the tensile bond strength between heat‐polymerized acrylic resin for ocular prostheses and silicone reliner, with and without the use of an adhesive primer. Materials and Methods: One‐hundred and sixty‐four acrylic resin specimens were fabricated and randomly distributed into four groups according to the type of surface treatment: Sofreliner Primer, NTP, Sofreliner Primer + NTP, and NTP + Sofreliner Primer. Two specimens interposed with relining material (Sofreliner) formed one test sample to perform the tensile bond strength tests, before (initial) and after storage (final) in saline solution (37°C, 90 days, n = 10). Surface characterization was performed by scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). The failure type was classified as cohesive, adhesive, or mixed. The data were analyzed statistically using the two‐way ANOVA and Tukey test, as well as the chi‐squared test ( α = 0.05), Bonferroni correction ( α = 0.005), and Spearman correlation coefficient ( α = 0.05). Results: The SEM and EDS analyses showed the presence of a thin, homogenous organic film in the groups treated with NTP. The NTP + Sofreliner Primer group presented the largest bond strength mean values in the initial period ( p < 0.05). Sofreliner Primer and NTP + Sofreliner Primer groups presented the first and second largest tensile bond strength mean values in the final period ( p < 0.05), respectively. NTP + Sofreliner Primer group also had the largest number of cohesive (70%, initial) and mixed (90%, final) failures. Conclusions: The NTP treatment performed before the primer application enhanced the bond between the acrylic resin ocular prosthesis and the Sofreliner silicone‐based reliner, even after 90 days of immersion in saline solution. … (more)
- Is Part Of:
- Journal of prosthodontics. Volume 28:Issue 6(2019)
- Journal:
- Journal of prosthodontics
- Issue:
- Volume 28:Issue 6(2019)
- Issue Display:
- Volume 28, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 28
- Issue:
- 6
- Issue Sort Value:
- 2019-0028-0006-0000
- Page Start:
- 692
- Page End:
- 700
- Publication Date:
- 2019-06-07
- Subjects:
- Acrylic resins -- artificial eye -- plasma gasses -- tensile strength
Prosthodontics -- Periodicals
Dental implants -- Periodicals
Dentistry -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1532-849X ↗
http://www.blackwell-synergy.com/servlet/useragent?func=showIssues&code=jopr ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jopr.13078 ↗
- Languages:
- English
- ISSNs:
- 1059-941X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5042.920000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11013.xml