Comparing the incidence of ventricular arrhythmias during epicardial ablation in swine versus canine models. Issue 7 (29th April 2019)
- Record Type:
- Journal Article
- Title:
- Comparing the incidence of ventricular arrhythmias during epicardial ablation in swine versus canine models. Issue 7 (29th April 2019)
- Main Title:
- Comparing the incidence of ventricular arrhythmias during epicardial ablation in swine versus canine models
- Authors:
- Caluori, Guido
Wojtaszczyk, Adam
Yasin, Omar
Pesl, Martin
Wolf, Jiří
Belaskova, Silvie
Crha, Michal
Sugrue, Alan
Vaidya, Vaibhav R.
Naksuk, Niyada
DeSimone, Christopher V.
Killu, Ammar M.
Padmanabhan, Deepak
Asirvatham, Samuel J.
Stárek, Zdeněk - Abstract:
- Abstract: Background: Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. Methods: We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine ( Sus Scrofa ) and canine ( Canis familiaris ) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. Results: Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97‐164.69, animal‐based odds ratio [OR]: .55, 95% CI: .23‐61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35‐9.55; P = .010). Conclusions: The swine myocardium is moreAbstract: Background: Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. Methods: We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine ( Sus Scrofa ) and canine ( Canis familiaris ) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. Results: Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97‐164.69, animal‐based odds ratio [OR]: .55, 95% CI: .23‐61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35‐9.55; P = .010). Conclusions: The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 7(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 7(2019)
- Issue Display:
- Volume 42, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2019-0042-0007-0000
- Page Start:
- 862
- Page End:
- 867
- Publication Date:
- 2019-04-29
- Subjects:
- animal model electrophysiology -- cardiovascular devices -- preclinical cardiology -- radiofrequency catheter ablation -- ventricular arrhythmia
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13698 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11013.xml