Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement. Issue 7 (29th April 2019)
- Record Type:
- Journal Article
- Title:
- Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement. Issue 7 (29th April 2019)
- Main Title:
- Cardiac conduction abnormalities associated with pacemaker implantation after transcatheter aortic valve replacement
- Authors:
- Cresse, Stephen
Eisenberg, Trevor
Alfonso, Carlos
Cohen, Mauricio G.
DeMarchena, Eduardo
Williams, Donald
Carrillo, Roger - Abstract:
- Abstract: Background: Complete heart block is a known complication after transcatheter aortic valve replacement (TAVR), often requiring pacemaker implantation within 24 hours of the procedure. However, clinical markers for delayed progression to complete heart block after TAVR remain unclear. Objectives: We examined electrocardiographic data that may correlate with delayed progression to complete heart block and need for pacemaker. Methods: This is a single‐center retrospective study of 608 patients who underwent TAVR between April 2008 and June 2017. We excluded 164 (27.0%) patients due to having a pacemaker before the procedure or expiring within 24 hours of the procedure (8, 1.3%). We excluded an additional 50 (8.2%) patients who received a pacemaker within 24 hours of the procedure. Electrocardiograms (EKGs) obtained after the procedure were compared to the preprocedural EKG to detect new changes. Results: Left bundle branch block, intraventricular conduction delay, left anterior fascicular block, and right bundle branch block were the most commonly seen conduction abnormalities after TAVR (25.1%, 10.9%, 7.5%, and 3.6%, respectively). Both left bundle branch block (odds ratio [OR] = 2.77 [95% confidence interval (CI): 1.24–6.22]) and right bundle branch block (OR = 13.2 [95% CI: 4.18–41.70]) carried an increased risk of pacemaker implantation after TAVR. Additionally, ΔPR greater than 40 ms from baseline also carried an increased risk of pacemaker implantation (OR = 3.53Abstract: Background: Complete heart block is a known complication after transcatheter aortic valve replacement (TAVR), often requiring pacemaker implantation within 24 hours of the procedure. However, clinical markers for delayed progression to complete heart block after TAVR remain unclear. Objectives: We examined electrocardiographic data that may correlate with delayed progression to complete heart block and need for pacemaker. Methods: This is a single‐center retrospective study of 608 patients who underwent TAVR between April 2008 and June 2017. We excluded 164 (27.0%) patients due to having a pacemaker before the procedure or expiring within 24 hours of the procedure (8, 1.3%). We excluded an additional 50 (8.2%) patients who received a pacemaker within 24 hours of the procedure. Electrocardiograms (EKGs) obtained after the procedure were compared to the preprocedural EKG to detect new changes. Results: Left bundle branch block, intraventricular conduction delay, left anterior fascicular block, and right bundle branch block were the most commonly seen conduction abnormalities after TAVR (25.1%, 10.9%, 7.5%, and 3.6%, respectively). Both left bundle branch block (odds ratio [OR] = 2.77 [95% confidence interval (CI): 1.24–6.22]) and right bundle branch block (OR = 13.2 [95% CI: 4.18–41.70]) carried an increased risk of pacemaker implantation after TAVR. Additionally, ΔPR greater than 40 ms from baseline also carried an increased risk of pacemaker implantation (OR = 3.53 [95% CI: 1.49–8.37]). Conclusion: Left bundle branch block, right bundle branch block, and ΔPR greater than 40 ms were all associated with delayed progression to complete heart block and need for pacemaker implantation after TAVR. … (more)
- Is Part Of:
- Pacing and clinical electrophysiology. Volume 42:Issue 7(2019)
- Journal:
- Pacing and clinical electrophysiology
- Issue:
- Volume 42:Issue 7(2019)
- Issue Display:
- Volume 42, Issue 7 (2019)
- Year:
- 2019
- Volume:
- 42
- Issue:
- 7
- Issue Sort Value:
- 2019-0042-0007-0000
- Page Start:
- 846
- Page End:
- 852
- Publication Date:
- 2019-04-29
- Subjects:
- EKG -- pacemaker implantation -- transcatheter aortic valve replacement
Cardiac pacing -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1540-8159 ↗
http://www.blackwell-synergy.com/rd.asp?goto=journal&code=pace ↗
http://www.futuraco.com/journalsf.htm ↗
http://onlinelibrary.wiley.com/ ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0147-8389;screen=info;ECOIP ↗ - DOI:
- 10.1111/pace.13695 ↗
- Languages:
- English
- ISSNs:
- 0147-8389
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6328.210000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 11013.xml