Meta‐analysis of drug eluting stents compared with bare metal stents in high bleeding risk patients undergoing percutaneous coronary interventions. Issue 1 (26th December 2018)
- Record Type:
- Journal Article
- Title:
- Meta‐analysis of drug eluting stents compared with bare metal stents in high bleeding risk patients undergoing percutaneous coronary interventions. Issue 1 (26th December 2018)
- Main Title:
- Meta‐analysis of drug eluting stents compared with bare metal stents in high bleeding risk patients undergoing percutaneous coronary interventions
- Authors:
- Neupane, Saroj
Khawaja, Owais
Edla, Sushruth
Singh, Hemindermeet
Othman, Hussein
Bossone, Eduardo
Yamasaki, Hiroshi
Rosman, Howard S.
Eggebrecht, Holger
Mehta, Rajendra H. - Abstract:
- Abstract: Objectives: To determine the efficacy and safety of drug‐eluting stents (DESs) and bare metal stents (BMSs) when used with short or tailored dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. Background: DES have been shown to reduce target lesion revascularization (TLR) as well as stent thrombosis (ST) compared to BMS in patients undergoing percutaneous coronary intervention (PCI). However, patients at HBR continue to receive BMS given the fear of bleeding or ST from premature discontinuation of DAPT in patients receiving DES. Methods: We performed a meta‐analysis of randomized controlled trials by performing systematic search for studies comparing DES with BMS in HBR patients using PUBMED, MEDLINE, and Cochrane Central, reported until March 1, 2018. Results: Three randomized controlled studies met the inclusion criteria with total of 4, 460 patients; 50% received DES. Major adverse cardiovascular event (MACE); composite of death, myocardial infarction (MI), and TLR, at 1 year was significantly lower (RR = 0.63, 95% CI 0.50–0.80) in DES group compared to BMS. This difference was primarily driven by lower TLR (RR = 0.46, 95% CI 0.35–0.61) in DES group. Definite or probable ST (RR = 0.59, 95% CI = 0.32–1.08) and major (RR = 0.94, 95% CI = 0.74–1.20) bleeding were similar. Conclusions: DES was associated with lower MACE without increased risk of bleeding or ST compared to BMS when used with short or tailored DAPT in patients with HBR.
- Is Part Of:
- Catheterization and cardiovascular interventions. Volume 94:Issue 1(2019)
- Journal:
- Catheterization and cardiovascular interventions
- Issue:
- Volume 94:Issue 1(2019)
- Issue Display:
- Volume 94, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 94
- Issue:
- 1
- Issue Sort Value:
- 2019-0094-0001-0000
- Page Start:
- 98
- Page End:
- 104
- Publication Date:
- 2018-12-26
- Subjects:
- bare metal stent -- drug‐eluting stent -- dual antiplatelet therapy -- high bleeding risk -- percutaneous coronary intervention -- stent thrombosis
Heart -- Diseases -- Diagnosis -- Periodicals
Cardiac catheterization -- Periodicals
616.1207572 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-726X ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/ccd.28045 ↗
- Languages:
- English
- ISSNs:
- 1522-1946
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3092.992000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 11006.xml