Implicit Sensing of Building Occupancy Count with Information and Communication Technology Data Sets. (15th June 2019)
- Record Type:
- Journal Article
- Title:
- Implicit Sensing of Building Occupancy Count with Information and Communication Technology Data Sets. (15th June 2019)
- Main Title:
- Implicit Sensing of Building Occupancy Count with Information and Communication Technology Data Sets
- Authors:
- Howard, Bianca
Acha, Salvador
Shah, Nilay
Polak, John - Abstract:
- Abstract: Occupancy count, i.e., the number of people in a space or building, is becoming an increasingly important measurement to model, predict, and minimize operational energy consumption. Explicit, hardware-based, occupancy counters have been proposed but wide scale adoption is limited due to the cost and invasiveness of system implementation. As an alternative approach, researchers propose using data from existing information and communication technology (ICT) systems to infer occupancy counts. In the reported work, three different data streams, security access data, wireless connectivity data, and computer activity data, from ICT systems in a medium sized office building were collected and compared to the counts of a commercially available occupancy counter over 59 working days. The occupancy counts from the ICT systems are compared to the commercial counter with and without calibration to determine the ability of the data sets to measure occupancy. Various transformations were explored as calibration techniques for the ICT data sets. Training sets of 24, 48, and 120 hours were employed to determine how long an external calibration system would need to be installed. The analysis found that calibration is required to provide accurate counts. While each ICT data set provides similar magnitudes and time series behavior, incorporating all three data streams in a two layer neural network with 1 week of training data provides the most accurate estimates against 5 performanceAbstract: Occupancy count, i.e., the number of people in a space or building, is becoming an increasingly important measurement to model, predict, and minimize operational energy consumption. Explicit, hardware-based, occupancy counters have been proposed but wide scale adoption is limited due to the cost and invasiveness of system implementation. As an alternative approach, researchers propose using data from existing information and communication technology (ICT) systems to infer occupancy counts. In the reported work, three different data streams, security access data, wireless connectivity data, and computer activity data, from ICT systems in a medium sized office building were collected and compared to the counts of a commercially available occupancy counter over 59 working days. The occupancy counts from the ICT systems are compared to the commercial counter with and without calibration to determine the ability of the data sets to measure occupancy. Various transformations were explored as calibration techniques for the ICT data sets. Training sets of 24, 48, and 120 hours were employed to determine how long an external calibration system would need to be installed. The analysis found that calibration is required to provide accurate counts. While each ICT data set provides similar magnitudes and time series behavior, incorporating all three data streams in a two layer neural network with 1 week of training data provides the most accurate estimates against 5 performance metrics. Whilst 1 week of data provides the best results, 24 hours is sufficient to develop similar levels of performance. Highlights: Information and Communication Technology (ICT) data is used to sense occupant count. Tier I sensors, sensors requiring no additional infrastructure, are evaluated. ICT-based Tier I Occupancy sensors are compared to a commercial occupancy counter. With calibration, ICT-based Tier I occupancy sensors can measure occupancy count. Computer activity data were capable of estimating arrival time with 97% accuracy. … (more)
- Is Part Of:
- Building and environment. Volume 157(2019)
- Journal:
- Building and environment
- Issue:
- Volume 157(2019)
- Issue Display:
- Volume 157, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 157
- Issue:
- 2019
- Issue Sort Value:
- 2019-0157-2019-0000
- Page Start:
- 297
- Page End:
- 308
- Publication Date:
- 2019-06-15
- Subjects:
- Tier I implicit occupancy sensing -- Occupancy count -- Information and communication technology -- Intelligent buildings
Buildings -- Environmental engineering -- Periodicals
Building -- Research -- Periodicals
Constructions -- Technique de l'environnement -- Périodiques
Electronic journals
696 - Journal URLs:
- http://www.sciencedirect.com/science/journal/03601323 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.buildenv.2019.04.015 ↗
- Languages:
- English
- ISSNs:
- 0360-1323
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 2359.355000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10979.xml