Enhanced microbubble contrast agent oscillation following 250 kHz insonation. Issue 1 (December 2018)
- Record Type:
- Journal Article
- Title:
- Enhanced microbubble contrast agent oscillation following 250 kHz insonation. Issue 1 (December 2018)
- Main Title:
- Enhanced microbubble contrast agent oscillation following 250 kHz insonation
- Authors:
- Ilovitsh, Tali
Ilovitsh, Asaf
Foiret, Josquin
Caskey, Charles
Kusunose, Jiro
Fite, Brett
Zhang, Hua
Mahakian, Lisa
Tam, Sarah
Butts-Pauly, Kim
Qin, Shengping
Ferrara, Katherine - Abstract:
- Abstract Microbubble contrast agents are widely used in ultrasound imaging and therapy, typically with transmission center frequencies in the MHz range. Currently, an ultrasound center frequency near 250 kHz is proposed for clinical trials in which ultrasound combined with microbubble contrast agents is applied to open the blood brain barrier, since at this low frequency focusing through the human skull to a predetermined location can be performed with reduced distortion and attenuation compared to higher frequencies. However, the microbubble vibrational response has not yet been carefully evaluated at this low frequency (an order of magnitude below the resonance frequency of these contrast agents). In the past, it was assumed that encapsulated microbubble expansion is maximized near the resonance frequency and monotonically decreases with decreasing frequency. Our results indicated that microbubble expansion was enhanced for 250 kHz transmission as compared with the 1 MHz center frequency. Following 250 kHz insonation, microbubble expansion increased nonlinearly with increasing ultrasonic pressure, and was accurately predicted by either the modified Rayleigh–Plesset equation for a clean bubble or the Marmottant model of a lipid-shelled microbubble. The expansion ratio reached 30-fold with 250 kHz at a peak negative pressure of 400 kPa, as compared to a measured expansion ratio of 1.6 fold for 1 MHz transmission at a similar peak negative pressure. Further, the range of peakAbstract Microbubble contrast agents are widely used in ultrasound imaging and therapy, typically with transmission center frequencies in the MHz range. Currently, an ultrasound center frequency near 250 kHz is proposed for clinical trials in which ultrasound combined with microbubble contrast agents is applied to open the blood brain barrier, since at this low frequency focusing through the human skull to a predetermined location can be performed with reduced distortion and attenuation compared to higher frequencies. However, the microbubble vibrational response has not yet been carefully evaluated at this low frequency (an order of magnitude below the resonance frequency of these contrast agents). In the past, it was assumed that encapsulated microbubble expansion is maximized near the resonance frequency and monotonically decreases with decreasing frequency. Our results indicated that microbubble expansion was enhanced for 250 kHz transmission as compared with the 1 MHz center frequency. Following 250 kHz insonation, microbubble expansion increased nonlinearly with increasing ultrasonic pressure, and was accurately predicted by either the modified Rayleigh–Plesset equation for a clean bubble or the Marmottant model of a lipid-shelled microbubble. The expansion ratio reached 30-fold with 250 kHz at a peak negative pressure of 400 kPa, as compared to a measured expansion ratio of 1.6 fold for 1 MHz transmission at a similar peak negative pressure. Further, the range of peak negative pressure yielding stable cavitationin vitro was narrow (~100 kPa) for the 250 kHz transmission frequency. Blood brain barrier opening usingin vivo transcranial ultrasound in mice followed the same trend as thein vitro experiments, and the pressure range for safe and effective treatment was 75–150 kPa. For pressures above 150 kPa, inertial cavitation and hemorrhage occurred. Therefore, we conclude that (1) at this low frequency, and for the large oscillations, lipid-shelled microbubbles can be approximately modeled as clean gas microbubbles and (2) the development of safe and successful protocols for therapeutic delivery to the brain utilizing 250 kHz or a similar center frequency requires consideration of the narrow pressure window between stable and inertial cavitation. … (more)
- Is Part Of:
- Scientific reports. Volume 8:Issue 1(2018)
- Journal:
- Scientific reports
- Issue:
- Volume 8:Issue 1(2018)
- Issue Display:
- Volume 8, Issue 1 (2018)
- Year:
- 2018
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2018-0008-0001-0000
- Page Start:
- 1
- Page End:
- 15
- Publication Date:
- 2018-12
- Subjects:
- Natural history -- Research -- Periodicals
Biology -- Research -- Periodicals
Physical sciences -- Research -- Periodicals
Earth sciences -- Research -- Periodicals
Environmental sciences -- Research -- Periodicals
502.85 - Journal URLs:
- http://www.nature.com/ ↗
http://www.nature.com/srep/index.html ↗ - DOI:
- 10.1038/s41598-018-34494-5 ↗
- Languages:
- English
- ISSNs:
- 2045-2322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10988.xml