A miniaturized low-power vector impedance analyser for accurate multi-parameter measurement. (October 2019)
- Record Type:
- Journal Article
- Title:
- A miniaturized low-power vector impedance analyser for accurate multi-parameter measurement. (October 2019)
- Main Title:
- A miniaturized low-power vector impedance analyser for accurate multi-parameter measurement
- Authors:
- Luciani, G.
Ramilli, R.
Romani, A.
Tartagni, M.
Traverso, P.A.
Crescentini, M. - Abstract:
- Highlights: A vector impedance analyser based on delta-sigma conversion. i) low-power, ii) high-integration, iii) multi-parameter and iv) high-accuracy. 4-Core prototype on a 3 × 6-cm PCB board: power <500 mW; mean uncertainty <0.14%. Indirect estimate of TDS deviates from reference value by less than 1.2%. Abstract: Distributed measurements are important in many application fields, from environment to biomedicine. In both cases, the sensor nodes employed in the measurement network have to satisfy many requirements; among them, the most important ones are: i ) low power consumption, ii ) miniaturization, iii ) adequate accuracy, and iv ) capability of multi-parameter measurement. This paper presents a Vector Impedance Analyser (VIA) architecture that satisfies these main requirements. The architecture is specifically devised to be interfaced with an array of impedimetric sensors for environmental applications, such as distributed water monitoring, or for mobile-Health/wearable biomedical devices. The proposed architecture is based on delta-sigma digital-to-analogue (D/A) conversion for the generation of the low-noise excitation and on band-pass delta-sigma analogue-to-digital (A/D) conversion for the low-power and high-accuracy acquisition of the impedimetric sensor response. The proposed combination of delta-sigma D/A and A/D conversion allows to i ) implement many measurement cores in a single silicon chip with reduced dimensions, ii ) achieve a fair accuracy/powerHighlights: A vector impedance analyser based on delta-sigma conversion. i) low-power, ii) high-integration, iii) multi-parameter and iv) high-accuracy. 4-Core prototype on a 3 × 6-cm PCB board: power <500 mW; mean uncertainty <0.14%. Indirect estimate of TDS deviates from reference value by less than 1.2%. Abstract: Distributed measurements are important in many application fields, from environment to biomedicine. In both cases, the sensor nodes employed in the measurement network have to satisfy many requirements; among them, the most important ones are: i ) low power consumption, ii ) miniaturization, iii ) adequate accuracy, and iv ) capability of multi-parameter measurement. This paper presents a Vector Impedance Analyser (VIA) architecture that satisfies these main requirements. The architecture is specifically devised to be interfaced with an array of impedimetric sensors for environmental applications, such as distributed water monitoring, or for mobile-Health/wearable biomedical devices. The proposed architecture is based on delta-sigma digital-to-analogue (D/A) conversion for the generation of the low-noise excitation and on band-pass delta-sigma analogue-to-digital (A/D) conversion for the low-power and high-accuracy acquisition of the impedimetric sensor response. The proposed combination of delta-sigma D/A and A/D conversion allows to i ) implement many measurement cores in a single silicon chip with reduced dimensions, ii ) achieve a fair accuracy/power trade-off, and iii ) tune the operative frequency in real time so as to span the target portion of the frequency domain. A prototype of the VIA is implemented in a 3 × 6-cm PCB board to investigate the potentialities of the architecture. The low-noise analogue circuits of the architecture are implemented in an Application Specific Integrated Circuit (ASIC), while part of the digital circuits are implemented on a commercial microcontroller for better testability purposes. The prototype embeds four independent cores to allow real-time multi-parameter measurement. To prove the performance of the proposed VIA, the prototype is characterized in terms of noise (input-referred noise between 20 mΩ and 70 mΩ in 10-Hz bandwidth, i.e. from 25 to 92 ppm of the full scale), accuracy (average uncertainty of 0.14% of the full scale for the magnitude and 0.72° for the argument, accounting for the limited accuracy of the reference instrument used for calibration), and power consumption (approximately 125 mW per-core including the power consumption of the microcontroller and the ancillary circuits used for power management and communication). The multi-parameter measurement capability is demonstrated by the realistic case-study of estimating the concentration of total dissolved solids in a potassium chloride (KCl) solution by means of direct concurrent measurements of conductivity and temperature. … (more)
- Is Part Of:
- Measurement. Volume 144(2019)
- Journal:
- Measurement
- Issue:
- Volume 144(2019)
- Issue Display:
- Volume 144, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 144
- Issue:
- 2019
- Issue Sort Value:
- 2019-0144-2019-0000
- Page Start:
- 388
- Page End:
- 401
- Publication Date:
- 2019-10
- Subjects:
- Impedance -- Impedance measurement -- Electrochemical impedance spectroscopy -- Environmental monitoring -- CT sensors -- Salinity measurement -- Sensor node -- Delta-sigma -- Water monitoring
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2019.05.003 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10971.xml