Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China. Issue 5 (September 2019)
- Record Type:
- Journal Article
- Title:
- Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China. Issue 5 (September 2019)
- Main Title:
- Insertion of peripherally inserted central catheters with intracavitary electrocardiogram guidance: A randomized multicenter study in China
- Authors:
- Yin, Yu-Xia
Gao, Wei
Li, Xu-Ying
Lu, Wei
Deng, Qian-Hong
Zhao, Cui-Yun
Liu, Xue-Rong
Zhou, Chao
Hou, Wen-Bo
Lu, Shou-Tao
Liu, Guang
Wang, Lu-Ning
Li, Mao-Quan
Zhang, Hai-Jun - Abstract:
- Introduction: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. Methods: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. Results: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%–93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%–81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity ofIntroduction: Ultrasound-guided venipuncture and tip location by intracavitary electrocardiogram have many advantages during the insertion of peripherally inserted central catheters, both in terms of safety and cost-effectiveness. Recently, a new tip-conductive peripherally inserted central catheters and new Doppler ultrasound device integrated with intracavitary electrocardiogram have been introduced into clinical practice in China. A randomized multicenter study (clinical trial no. NCT03230357) was performed to verify the feasibility and accuracy of intracavitary electrocardiogram, as performed with this new peripherally inserted central catheters and device. Methods: Our study enrolled a total of 2250 adult patients in 10 different Chinese hospitals. The patients were randomly assigned to either the study group (intracavitary electrocardiogram) or the control group (anatomical landmark guidance) in a 2:1 allocation. Ultrasound was used in both groups for venipuncture and tip navigation. All patients underwent chest X-ray after the procedure to verify the position of the catheter tip. Results: No insertion-related complications were reported in either group. In the study group, first-attempt successful tip location was 91.7% (95% confidence interval: 90.3%–93.1%), significantly higher than 78.9% (95% confidence interval: 76.0%–81.9%) observed in the control group (p < 0.001). As evaluated by post-procedural chest X-ray, tip location in the study group had a sensitivity of 99.3% (95% confidence interval: 98.8%–99.7%), significantly higher than 86.8% (95% confidence interval: 84.4%–89.2%) observed in the anatomical landmark group (p < 0.001). Conclusion: These results indicated that during peripherally inserted central catheters insertion in adult patients, tip location with intracavitary electrocardiogram guidance, as carried out by a new tip-conductive peripherally inserted central catheters and intracavitary electrocardiogram integrated ultrasound device, was more effective and more accurate than tip location using anatomical landmarks. … (more)
- Is Part Of:
- Journal of vascular access. Volume 20:Issue 5(2019)
- Journal:
- Journal of vascular access
- Issue:
- Volume 20:Issue 5(2019)
- Issue Display:
- Volume 20, Issue 5 (2019)
- Year:
- 2019
- Volume:
- 20
- Issue:
- 5
- Issue Sort Value:
- 2019-0020-0005-0000
- Page Start:
- 524
- Page End:
- 529
- Publication Date:
- 2019-09
- Subjects:
- Peripherally inserted central catheters -- intracavitary electrocardiogram -- tip location -- ultrasound guidance
Arterial catheterization -- Periodicals
Intravenous catheterization -- Periodicals
612.13 - Journal URLs:
- http://journals.sagepub.com/home/jva ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1129729818819732 ↗