Impact of a novel exponential weighted 4DCT reconstruction algorithm. (11th September 2018)
- Record Type:
- Journal Article
- Title:
- Impact of a novel exponential weighted 4DCT reconstruction algorithm. (11th September 2018)
- Main Title:
- Impact of a novel exponential weighted 4DCT reconstruction algorithm
- Authors:
- Morris, Eric D.
Kim, Joshua P.
Klahr, Paul
Glide‐Hurst, Carri K. - Abstract:
- Abstract: Purpose: This work characterizes a novel exponential 4DCT reconstruction algorithm (EXPO), in phantom and patient, to determine its impact on image quality as compared to the standard cosine‐squared weighted 4DCT reconstruction. Methods: A motion platform translated objects in the superior–inferior (S‐I) direction at varied breathing rates (8–20 bpm) and couch pitches (0.06–0.1) to evaluate interplay between parameters. Ten‐phase 4DCTs were acquired and data were reconstructed with cosine squared and EXPO weighting. To quantify the magnitude of image blur, objects were translated in the anterior–posterior (A‐P) and S‐I directions for full‐width half maximum (FWHM) analysis between both 4DCT algorithms and a static case. 4DCT sinogram data for 10 patients were retrospectively reconstructed using both weighting factors. Image subtractions elucidated intensity and boundary differences. Subjective image quality grading (presence of image artifacts, noise, spatial resolution (i.e., lung/liver boundary sharpness), and overall image quality) was conducted yielding 200 evaluations. Results: After taking static object size into account, the FWHM of EXPO reconstructions in the A‐P direction was 3.3 ± 1.7 mm (range: 0–4.9) as compared to cosine squared 9.8 ± 4.0 mm (range: 2.6–14.4). The FWHM of objects translated in the S‐I direction reconstructed with EXPO agreed better with the static FWHM than the cosine‐squared reconstructions. Slower breathing periods, faster couchAbstract: Purpose: This work characterizes a novel exponential 4DCT reconstruction algorithm (EXPO), in phantom and patient, to determine its impact on image quality as compared to the standard cosine‐squared weighted 4DCT reconstruction. Methods: A motion platform translated objects in the superior–inferior (S‐I) direction at varied breathing rates (8–20 bpm) and couch pitches (0.06–0.1) to evaluate interplay between parameters. Ten‐phase 4DCTs were acquired and data were reconstructed with cosine squared and EXPO weighting. To quantify the magnitude of image blur, objects were translated in the anterior–posterior (A‐P) and S‐I directions for full‐width half maximum (FWHM) analysis between both 4DCT algorithms and a static case. 4DCT sinogram data for 10 patients were retrospectively reconstructed using both weighting factors. Image subtractions elucidated intensity and boundary differences. Subjective image quality grading (presence of image artifacts, noise, spatial resolution (i.e., lung/liver boundary sharpness), and overall image quality) was conducted yielding 200 evaluations. Results: After taking static object size into account, the FWHM of EXPO reconstructions in the A‐P direction was 3.3 ± 1.7 mm (range: 0–4.9) as compared to cosine squared 9.8 ± 4.0 mm (range: 2.6–14.4). The FWHM of objects translated in the S‐I direction reconstructed with EXPO agreed better with the static FWHM than the cosine‐squared reconstructions. Slower breathing periods, faster couch pitches, and intermediate 4DCT phases had the largest reductions of blurring with EXPO. 18 of 60 comparisons of artifacts were improved with EXPO reconstruction, whereas no appreciable changes were observed in image quality scores. In 18 of 20 cases, EXPO provided sharper images although the reduced projections also increased baseline noise. Conclusion: Exponential weighted 4DCT offers potential for reducing image blur (i.e., improving image sharpness) in 4DCT with a tendency to reduce artifacts. Future work will involve evaluating the impact on treatment planning including delineation ability and dose calculation. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 6(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 6(2018)
- Issue Display:
- Volume 19, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 6
- Issue Sort Value:
- 2018-0019-0006-0000
- Page Start:
- 217
- Page End:
- 225
- Publication Date:
- 2018-09-11
- Subjects:
- 4DCT -- artifacts -- reconstruction
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12423 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10961.xml