A clinical 3D/4D CBCT‐based treatment dose monitoring system. (10th October 2018)
- Record Type:
- Journal Article
- Title:
- A clinical 3D/4D CBCT‐based treatment dose monitoring system. (10th October 2018)
- Main Title:
- A clinical 3D/4D CBCT‐based treatment dose monitoring system
- Authors:
- Qin, An
Gersten, David
Liang, Jian
Liu, Qiang
Grill, Inga
Guerrero, Thomas
Stevens, Craig
Yan, Di - Abstract:
- Abstract: To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx‐Dose) reconstruction system based on three‐dimensional (3D)/four‐dimensional (4D)‐cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for lung cancer patient treated by stereotactic body radiation therapy (SBRT). This system integrates with our treatment planning system (TPS), Linacs recording and verification system (R&V), and CBCT imaging system, consisting of three modules: Treatment Schedule Monitoring module (TSM), pseudo‐CT Generating module (PCG), and Treatment Dose Reconstruction/evaluation module (TDR). TSM watches the treatment progress in the R&V system and triggers the PCG module when new CBCT is available. PCG retrieves the CBCTs and performs planning CT to CBCT deformable registration (DIR) to generate pseudo‐CT. The 4D‐CBCT images are taken for target localization and correction in lung cancer patient before treatment. To take full advantage of the valuable information carried by 4D‐CBCT, a novel phase‐matching DIR scheme was developed to generate 4D pseudo‐CT images for 4D dose reconstruction. Finally, TDR module creates TPS scripts to automate Tx‐Dose calculation on the pseudo‐CT images. Both initial quantitative commissioning and patient‐specific qualitative quality assurance of the DIR tool were utilized to ensure the DIR quality. The treatment doses of ten patientsAbstract: To monitor delivered dose and trigger plan adaptation when deviation becomes unacceptable, a clinical treatment dose (Tx‐Dose) reconstruction system based on three‐dimensional (3D)/four‐dimensional (4D)‐cone beam computed tomograpy (CBCT) images was developed and evaluated on various treatment sites, particularly for lung cancer patient treated by stereotactic body radiation therapy (SBRT). This system integrates with our treatment planning system (TPS), Linacs recording and verification system (R&V), and CBCT imaging system, consisting of three modules: Treatment Schedule Monitoring module (TSM), pseudo‐CT Generating module (PCG), and Treatment Dose Reconstruction/evaluation module (TDR). TSM watches the treatment progress in the R&V system and triggers the PCG module when new CBCT is available. PCG retrieves the CBCTs and performs planning CT to CBCT deformable registration (DIR) to generate pseudo‐CT. The 4D‐CBCT images are taken for target localization and correction in lung cancer patient before treatment. To take full advantage of the valuable information carried by 4D‐CBCT, a novel phase‐matching DIR scheme was developed to generate 4D pseudo‐CT images for 4D dose reconstruction. Finally, TDR module creates TPS scripts to automate Tx‐Dose calculation on the pseudo‐CT images. Both initial quantitative commissioning and patient‐specific qualitative quality assurance of the DIR tool were utilized to ensure the DIR quality. The treatment doses of ten patients (six SBRT‐lung, two head and neck (HN), one breast and one prostate cancer patients) were retrospectively constructed and evaluated. The target registration error (mean ± STD: 1.05 ± 1.13 mm) of the DIR tool is comparable to the interobserver uncertainty (0.88 ± 1.31 mm) evaluated by a publically available lung‐landmarks dataset. For lung SBRT patients, the D99 of the final cumulative Tx‐Dose of GTV is 93.8 ± 5.5% (83.7–100.1%) of the originally planned D99 . CTV D99 decreases by 3% and mean ipsilateral parotid dose increases by 11.5% for one of the two HN patients. In conclusion, we have demonstrated the feasibility and effectiveness of a treatment dose verification system in our clinical setting. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 19:Number 6(2018)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 19:Number 6(2018)
- Issue Display:
- Volume 19, Issue 6 (2018)
- Year:
- 2018
- Volume:
- 19
- Issue:
- 6
- Issue Sort Value:
- 2018-0019-0006-0000
- Page Start:
- 166
- Page End:
- 176
- Publication Date:
- 2018-10-10
- Subjects:
- 4D‐CBCT -- adaptive radiotherapy -- CBCT -- IGRT -- treatment dose
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.12474 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10961.xml