Lactated Ringer-based storage solutions are equally well suited for the storage of fresh osteochondral allografts as cell culture medium-based storage solutions. Issue 7 (July 2017)
- Record Type:
- Journal Article
- Title:
- Lactated Ringer-based storage solutions are equally well suited for the storage of fresh osteochondral allografts as cell culture medium-based storage solutions. Issue 7 (July 2017)
- Main Title:
- Lactated Ringer-based storage solutions are equally well suited for the storage of fresh osteochondral allografts as cell culture medium-based storage solutions
- Authors:
- Harb, Afif
von Horn, Alexander
Gocalek, Kornelia
Schäck, Luisa Marilena
Clausen, Jan
Krettek, Christian
Noack, Sandra
Neunaber, Claudia - Abstract:
- Abstract: Background: Due to the rising interest in Europe to treat large cartilage defects with osteochondrale allografts, research aims to find a suitable solution for long-term storage of osteochondral allografts. This is further encouraged by the fact that legal restrictions currently limit the use of the ingredients from animal or human sources that are being used in other regions of the world (e.g. in the USA). Therefore, the aim of this study was A) to analyze if a Lactated Ringer (LR) based solution is as efficient as a Dulbecco modified Eagle's minimal essential medium (DMEM) in maintaining chondrocyte viability and B) at which storage temperature (4 °C vs. 37 °C) chondrocyte survival of the osteochondral allograft is optimally sustained. Methods: 300 cartilage grafts were collected from knees of ten one year‐old Black Head German Sheep. The grafts were stored in four different storage solutions (one of them DMEM-based, the other three based on Lactated Ringer Solution), at two different temperatures (4 and 37 °C) for 14 and 56 days. At both points in time, chondrocyte survival as well as death rate, Glycosaminoglycan (GAG) content, and Hydroxyproline (HP) concentration were measured and compared between the grafts stored in the different solutions and at the different temperatures. Results: Independent of the storage solutions tested, chondrocyte survival rates were higher when stored at 4 °C compared to storage at 37 °C both after short-term (14 days) andAbstract: Background: Due to the rising interest in Europe to treat large cartilage defects with osteochondrale allografts, research aims to find a suitable solution for long-term storage of osteochondral allografts. This is further encouraged by the fact that legal restrictions currently limit the use of the ingredients from animal or human sources that are being used in other regions of the world (e.g. in the USA). Therefore, the aim of this study was A) to analyze if a Lactated Ringer (LR) based solution is as efficient as a Dulbecco modified Eagle's minimal essential medium (DMEM) in maintaining chondrocyte viability and B) at which storage temperature (4 °C vs. 37 °C) chondrocyte survival of the osteochondral allograft is optimally sustained. Methods: 300 cartilage grafts were collected from knees of ten one year‐old Black Head German Sheep. The grafts were stored in four different storage solutions (one of them DMEM-based, the other three based on Lactated Ringer Solution), at two different temperatures (4 and 37 °C) for 14 and 56 days. At both points in time, chondrocyte survival as well as death rate, Glycosaminoglycan (GAG) content, and Hydroxyproline (HP) concentration were measured and compared between the grafts stored in the different solutions and at the different temperatures. Results: Independent of the storage solutions tested, chondrocyte survival rates were higher when stored at 4 °C compared to storage at 37 °C both after short-term (14 days) and long-term storage (56 days). At no point in time did the DMEM-based solution show a superior chondrocyte survival compared to lactated Ringer based solution. GAG and HP content were comparable across all time points, temperatures and solutions. Conclusion: LR based solutions that contain only substances that are approved in Germany may be just as efficient for storing grafts as the USA DMEM-based solution gold standard. Moreover, in the present experiment storage of osteochondral allografts at 4 °C was superior to storage at 37 °C. … (more)
- Is Part Of:
- Injury. Volume 48:Issue 7(2017)
- Journal:
- Injury
- Issue:
- Volume 48:Issue 7(2017)
- Issue Display:
- Volume 48, Issue 7 (2017)
- Year:
- 2017
- Volume:
- 48
- Issue:
- 7
- Issue Sort Value:
- 2017-0048-0007-0000
- Page Start:
- 1302
- Page End:
- 1308
- Publication Date:
- 2017-07
- Subjects:
- Osteochondral allograft -- Graft survival -- Long term-storage of grafts -- Cartilage -- Joint defects
Wounds and injuries -- Surgery -- Periodicals
Accidents -- Periodicals
Wounds and Injuries -- surgery -- Periodicals
Lésions et blessures -- Chirurgie -- Périodiques
Electronic journals
Electronic journals
617.1 - Journal URLs:
- http://www.sciencedirect.com/science/journal/00201383 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/00201383 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/00201383 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.injury.2017.05.009 ↗
- Languages:
- English
- ISSNs:
- 0020-1383
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4514.400000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10953.xml