The Barrow Biomimetic Spine: Face, Content, and Construct Validity of a 3D-Printed Spine Model for Freehand and Minimally Invasive Pedicle Screw Insertion. Issue 6 (September 2019)
- Record Type:
- Journal Article
- Title:
- The Barrow Biomimetic Spine: Face, Content, and Construct Validity of a 3D-Printed Spine Model for Freehand and Minimally Invasive Pedicle Screw Insertion. Issue 6 (September 2019)
- Main Title:
- The Barrow Biomimetic Spine: Face, Content, and Construct Validity of a 3D-Printed Spine Model for Freehand and Minimally Invasive Pedicle Screw Insertion
- Authors:
- Bohl, Michael A.
Mauria, Rohit
Zhou, James J.
Mooney, Michael A.
DiDomenico, Joseph D.
McBryan, Sarah
Cavallo, Claudio
Nakaji, Peter
Chang, Steve W.
Uribe, Juan S.
Turner, Jay D.
Kakarla, U. Kumar - Abstract:
- Study Design: Description and evaluation of a novel surgical training platform. Objectives: The purpose of this study was to investigate the face, content, and construct validity of 5 novel surgical training models that simulate freehand and percutaneous (minimally invasive surgery [MIS]) pedicle screw placement. Methods: Five spine models were developed by residents: 3 for freehand pedicle screw training (models A-C) and 2 for MIS pedicle screw training (models D and E). Attending spine surgeons evaluated each model and, using a 20-point Likert-type scale, answered survey questions on model face, content, and construct validity. Scores were statistically evaluated and compared using means, standard deviations, and analysis of variance between models and between surgeons. Results: Among the freehand models, model C demonstrated the highest overall validity, with mean face (15.67 ± 5.49), content (19.17 ± 0.59), and construct (18.83 ± 0.24) validity all measuring higher than the other freehand models. For the MIS models, model D had the highest validity scores (face, content, and construct validity of 11.67 ± 3.77, 18.17 ± 2.04, and 17.00 ± 3.46, respectively). The 3 freehand models differed significantly in content validity scores ( P = .002) as did the 2 MIS models ( P < .001). The testing surgeons' overall validity scores were significantly different for models A ( P = .005) and E ( P < .001). Conclusions: A 3-dimensional-printed spine model with incorporated bone bleedingStudy Design: Description and evaluation of a novel surgical training platform. Objectives: The purpose of this study was to investigate the face, content, and construct validity of 5 novel surgical training models that simulate freehand and percutaneous (minimally invasive surgery [MIS]) pedicle screw placement. Methods: Five spine models were developed by residents: 3 for freehand pedicle screw training (models A-C) and 2 for MIS pedicle screw training (models D and E). Attending spine surgeons evaluated each model and, using a 20-point Likert-type scale, answered survey questions on model face, content, and construct validity. Scores were statistically evaluated and compared using means, standard deviations, and analysis of variance between models and between surgeons. Results: Among the freehand models, model C demonstrated the highest overall validity, with mean face (15.67 ± 5.49), content (19.17 ± 0.59), and construct (18.83 ± 0.24) validity all measuring higher than the other freehand models. For the MIS models, model D had the highest validity scores (face, content, and construct validity of 11.67 ± 3.77, 18.17 ± 2.04, and 17.00 ± 3.46, respectively). The 3 freehand models differed significantly in content validity scores ( P = .002) as did the 2 MIS models ( P < .001). The testing surgeons' overall validity scores were significantly different for models A ( P = .005) and E ( P < .001). Conclusions: A 3-dimensional-printed spine model with incorporated bone bleeding and silicone rubber soft tissue was scored as having very high content and construct validity for simulating freehand pedicle screw insertion. These data has informed the further development of several surgical training models that hold great potential as educational adjuncts in surgical training programs. … (more)
- Is Part Of:
- Global spine journal. Volume 9:Issue 6(2019)
- Journal:
- Global spine journal
- Issue:
- Volume 9:Issue 6(2019)
- Issue Display:
- Volume 9, Issue 6 (2019)
- Year:
- 2019
- Volume:
- 9
- Issue:
- 6
- Issue Sort Value:
- 2019-0009-0006-0000
- Page Start:
- 635
- Page End:
- 641
- Publication Date:
- 2019-09
- Subjects:
- medical education -- model validity -- spine -- surgical training
Spine -- Diseases -- Periodicals
Spine -- Diseases -- Treatment -- Periodicals
Spine -- Abnormalities -- Periodicals
Spine -- Surgery -- Periodicals
616.73 - Journal URLs:
- http://www.thieme.com/ ↗
- DOI:
- 10.1177/2192568218824080 ↗
- Languages:
- English
- ISSNs:
- 2192-5682
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10941.xml