Fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methylsiloxanes (cVMSs) in indoor air from occupational and home environments. (October 2018)
- Record Type:
- Journal Article
- Title:
- Fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methylsiloxanes (cVMSs) in indoor air from occupational and home environments. (October 2018)
- Main Title:
- Fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methylsiloxanes (cVMSs) in indoor air from occupational and home environments
- Authors:
- Sha, Bo
Dahlberg, Anna-Karin
Wiberg, Karin
Ahrens, Lutz - Abstract:
- Abstract: Indoor air samples were collected from private homes and various occupational indoor environments using passive air sampler and analysed for fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methyl siloxanes (cVMSs). The aim was to investigate their occurrence in indoor air, factors that may affect their presence and human daily exposure dose (DED) via inhalation. In general, levels of cVMSs were 3–4 orders of magnitude greater than the other compound classes. OPFRs concentration was found significantly higher than BFRs in indoor air. The most abundant compounds in each chemical class were 8:2 FTOH, 2, 4, 6-TBP, TNBP and TCEP and decamethylcyclopentasiloxane (D5). Home samples contained higher level of FTOHs, BFRs and cVMSs than occupational environments, whereas concentration of OPFRs in office samples were higher. BFRs concentrations were significantly correlated with building age and with the number of electronic/electrical devices at the sampling sites. Moreover, significantly lower levels of FTOHs and cVMSs were observed in rooms with forced-ventilation system. Estimated DED via inhalation was significantly higher at home than in office and the total DED was on average 3–5 orders of magnitude lower than the reference value. Graphical abstract: Highlights: PFASs, BFRs, OPFRs and cVMSs present in residential and occupational indoor air. Building ages and brominated flame retardantAbstract: Indoor air samples were collected from private homes and various occupational indoor environments using passive air sampler and analysed for fluorotelomer alcohols (FTOHs), brominated flame retardants (BFRs), organophosphorus flame retardants (OPFRs) and cyclic volatile methyl siloxanes (cVMSs). The aim was to investigate their occurrence in indoor air, factors that may affect their presence and human daily exposure dose (DED) via inhalation. In general, levels of cVMSs were 3–4 orders of magnitude greater than the other compound classes. OPFRs concentration was found significantly higher than BFRs in indoor air. The most abundant compounds in each chemical class were 8:2 FTOH, 2, 4, 6-TBP, TNBP and TCEP and decamethylcyclopentasiloxane (D5). Home samples contained higher level of FTOHs, BFRs and cVMSs than occupational environments, whereas concentration of OPFRs in office samples were higher. BFRs concentrations were significantly correlated with building age and with the number of electronic/electrical devices at the sampling sites. Moreover, significantly lower levels of FTOHs and cVMSs were observed in rooms with forced-ventilation system. Estimated DED via inhalation was significantly higher at home than in office and the total DED was on average 3–5 orders of magnitude lower than the reference value. Graphical abstract: Highlights: PFASs, BFRs, OPFRs and cVMSs present in residential and occupational indoor air. Building ages and brominated flame retardant levels were positively correlated. Ventilation conditions may have an influence on the presence of indoor contaminants. Estimation of human exposure via inhalation to four emerging contaminant classes. Abstract : To close the knowledge gap of emerging pollutants in indoor air in occupational and home environments, this study examined the presence of four different categories of emerging pollutants in various indoor environments using passive sampling, to investigate factors that affect their occurrence and estimate human exposure via inhalation. … (more)
- Is Part Of:
- Environmental pollution. Volume 241(2018)
- Journal:
- Environmental pollution
- Issue:
- Volume 241(2018)
- Issue Display:
- Volume 241, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 241
- Issue:
- 2018
- Issue Sort Value:
- 2018-0241-2018-0000
- Page Start:
- 319
- Page End:
- 330
- Publication Date:
- 2018-10
- Subjects:
- Pollution -- Periodicals
Pollution -- Environmental aspects -- Periodicals
Environmental Pollution -- Periodicals
Pollution -- Périodiques
Pollution -- Aspect de l'environnement -- Périodiques
Pollution -- Effets physiologiques -- Périodiques
Pollution
Pollution -- Environmental aspects
Periodicals
Electronic journals
363.73 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02697491 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.envpol.2018.04.032 ↗
- Languages:
- English
- ISSNs:
- 0269-7491
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3791.539000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10921.xml