Experimental study of Pipe-Fuse Damper for passive energy dissipation in structures. (September 2018)
- Record Type:
- Journal Article
- Title:
- Experimental study of Pipe-Fuse Damper for passive energy dissipation in structures. (September 2018)
- Main Title:
- Experimental study of Pipe-Fuse Damper for passive energy dissipation in structures
- Authors:
- Aghlara, Reza
Tahir, Mahmood Md.
Adnan, Azlan Bin - Abstract:
- Abstract: This study presents a novel passive metallic damper, Pipe-Fuse Damper (PFD), to improve the seismic response of structures with dissipation of the earthquake energy. The Fuse Damper (FD) was recently introduced by using steel bars as fuses, Bar-Fuse Damper (BFD), and its performance was evaluated experimentally. The Fuse Damper (FD) is built using common cross-sections found in engineering structures, such as square hollow sections (SHS) and U-shaped sections as well as metal sheets. As a special feature, the Fuse Damper (FD) uses replaceable components as an energy-absorber part with both flexural and tensile energy dissipating mechanisms. In this study, the Fuse Damper (FD) was evaluated with components of steel pipes experimentally and numerically. To assess the individual performance of this damper, the Pipe-Fuse Damper (PFD), a series of monotonic and cyclic experiments were conducted on real-scale specimens. The studied parameters for this replaceable element in the experiments were the number of pipes and their diameter, length, and thickness. The results indicate that, in addition to demonstrating a stable hysteretic behaviour and considerable energy dissipation within an appropriate displacement reversal, the proposed damper offers the easy replacement of pipe components after each failure. Moreover, the Pipe-Fuse Damper (PFD) showed less pinching effects on its hysteresis and a higher energy dissipation compared to the Bar-Fuse Damper (BFD) under the sameAbstract: This study presents a novel passive metallic damper, Pipe-Fuse Damper (PFD), to improve the seismic response of structures with dissipation of the earthquake energy. The Fuse Damper (FD) was recently introduced by using steel bars as fuses, Bar-Fuse Damper (BFD), and its performance was evaluated experimentally. The Fuse Damper (FD) is built using common cross-sections found in engineering structures, such as square hollow sections (SHS) and U-shaped sections as well as metal sheets. As a special feature, the Fuse Damper (FD) uses replaceable components as an energy-absorber part with both flexural and tensile energy dissipating mechanisms. In this study, the Fuse Damper (FD) was evaluated with components of steel pipes experimentally and numerically. To assess the individual performance of this damper, the Pipe-Fuse Damper (PFD), a series of monotonic and cyclic experiments were conducted on real-scale specimens. The studied parameters for this replaceable element in the experiments were the number of pipes and their diameter, length, and thickness. The results indicate that, in addition to demonstrating a stable hysteretic behaviour and considerable energy dissipation within an appropriate displacement reversal, the proposed damper offers the easy replacement of pipe components after each failure. Moreover, the Pipe-Fuse Damper (PFD) showed less pinching effects on its hysteresis and a higher energy dissipation compared to the Bar-Fuse Damper (BFD) under the same conditions. Highlights: A novel metallic yield damper, Pipe-Fuse Damper (PFD), was developed from common steel sections in engineering structures. The PFD functions as an energy-dissipating fuse in system through replaceable steel pipe components. The key feature of PFD: the fuse-like components can be easily replaced in case of failure. The PFD can furnish an equivalent viscous damping ratio in a range of 0.25 to 0.80. The unit weight of these sacrificial elements can sustain 41 kN force and absorb 9 kJ of input energy on average. … (more)
- Is Part Of:
- Journal of constructional steel research. Volume 148(2018)
- Journal:
- Journal of constructional steel research
- Issue:
- Volume 148(2018)
- Issue Display:
- Volume 148, Issue 2018 (2018)
- Year:
- 2018
- Volume:
- 148
- Issue:
- 2018
- Issue Sort Value:
- 2018-0148-2018-0000
- Page Start:
- 351
- Page End:
- 360
- Publication Date:
- 2018-09
- Subjects:
- Passive control -- Metallic yield damper -- Earthquake energy dissipation -- Fuse Damper (FD) -- Pipe-Fuse Damper (PFD)
Steel, Structural -- Periodicals
Building, Iron and steel -- Periodicals
Acier de construction -- Périodiques
Construction métallique -- Périodiques
624.1821 - Journal URLs:
- http://www.sciencedirect.com/science/journal/0143974X ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcsr.2018.06.004 ↗
- Languages:
- English
- ISSNs:
- 0143-974X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4965.193000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10932.xml