Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement. (July 2019)
- Record Type:
- Journal Article
- Title:
- Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement. (July 2019)
- Main Title:
- Knee and hip strength measurements obtained by a hand-held dynamometer stabilized by a belt and an examiner demonstrate parallel reliability but not agreement
- Authors:
- Florencio, Lidiane L.
Martins, Jaqueline
da Silva, Marcelo R.B.
da Silva, Janaina R.
Bellizzi, Gustavo L.
Bevilaqua-Grossi, Débora - Abstract:
- Abstract: Objectives: To verify the intrasession reliability and the agreement between strength measurement of hip and knee muscles using hand-held dynamometer stabilized by a belt or by an examiner. Design: Test-retest design. Setting: Knee and hip muscles strength were measured bilaterally using hand-held dynamometer stabilized by a belt and by an examiner. Participants: 24 young and healthy participants. Main outcome measures: The reliability was verified by the intraclass correlation coefficient2, 1 and the standard error of measurement. Agreement between stabilization methods was verified by the Bland Altman's method. Results: Reliability was excellent for all muscle groups when stabilized by a belt (intraclass correlation coefficient = 0.78 to 0.95) and by the examiner (intraclass correlation coefficient = 0.83 to 0.97); standard error of measurement ranged between 1kgf to 4kgf at both methods, but they are proportionally lower when stabilized by the examiner. No agreement between both methods was identified for all knee strength measurements and for bilateral hip flexion, right internal and external rotation and left adduction. Conclusions: The hand-held dynamometer is reliable for hip and knee strength evaluation despite of the stabilization method. However, for the majority of the movements, greater strength and lower error are expected when the examiner stabilizes it. Highlights: Hand-held dynamometry is reliable, despite the stabilization method. StabilizationAbstract: Objectives: To verify the intrasession reliability and the agreement between strength measurement of hip and knee muscles using hand-held dynamometer stabilized by a belt or by an examiner. Design: Test-retest design. Setting: Knee and hip muscles strength were measured bilaterally using hand-held dynamometer stabilized by a belt and by an examiner. Participants: 24 young and healthy participants. Main outcome measures: The reliability was verified by the intraclass correlation coefficient2, 1 and the standard error of measurement. Agreement between stabilization methods was verified by the Bland Altman's method. Results: Reliability was excellent for all muscle groups when stabilized by a belt (intraclass correlation coefficient = 0.78 to 0.95) and by the examiner (intraclass correlation coefficient = 0.83 to 0.97); standard error of measurement ranged between 1kgf to 4kgf at both methods, but they are proportionally lower when stabilized by the examiner. No agreement between both methods was identified for all knee strength measurements and for bilateral hip flexion, right internal and external rotation and left adduction. Conclusions: The hand-held dynamometer is reliable for hip and knee strength evaluation despite of the stabilization method. However, for the majority of the movements, greater strength and lower error are expected when the examiner stabilizes it. Highlights: Hand-held dynamometry is reliable, despite the stabilization method. Stabilization method influences results in lower limb measurements. Lower error and greater strength are expected when the examiner stabilizes it. … (more)
- Is Part Of:
- Physical therapy in sport. Volume 38(2019)
- Journal:
- Physical therapy in sport
- Issue:
- Volume 38(2019)
- Issue Display:
- Volume 38, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 38
- Issue:
- 2019
- Issue Sort Value:
- 2019-0038-2019-0000
- Page Start:
- 115
- Page End:
- 122
- Publication Date:
- 2019-07
- Subjects:
- Muscle strength -- Knee -- Hip -- Reproducibility of results
Sports physical therapy -- Periodicals
Sports injuries -- Patients -- Rehabilitation -- Periodicals
Athletic Injuries -- diagnosis -- Periodicals
Athletic Injuries -- therapy -- Periodicals
Physical Therapy -- Periodicals
Sports Medicine -- Periodicals
615.82088796 - Journal URLs:
- http://www.sciencedirect.com/science/journal/1466853X ↗
http://www.clinicalkey.com/dura/browse/journalIssue/1466853X ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/1466853X ↗
http://www.elsevier.com/journals ↗
http://www.harcourt-international.com/journal ↗ - DOI:
- 10.1016/j.ptsp.2019.04.011 ↗
- Languages:
- English
- ISSNs:
- 1466-853X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6476.350650
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 10919.xml